Sensitivity study of an automated system for daily patient QA using EPID exit dose images

Abstract: The dosimetric consequences of errors in patient setup or beam delivery and anatomical changes are not readily known. A new product, PerFRACTION (Sun Nuclear Corporation), is designed to identify these errors by comparing the exit dose image measured on an electronic portal imaging device (EPID) from each field of each fraction to those from baseline fraction images. This work investigates the sensitivity of PerFRACTION to detect the deviation caused by these errors in a variety of realistic scenarios. Integra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
41
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(44 citation statements)
references
References 15 publications
2
41
1
Order By: Relevance
“…In addition, intrafractional motion may have occurred, because the shoulder could not be immobilized with the thermoplastic shell. Zhuang et al reported that a setup error as small as 1 mm and 0.5° could be detected using an anthropomorphic phantom with the PerFRACTION software . As described above, the lack of a setup error evaluation was a limitation of our study.…”
Section: Discussionmentioning
confidence: 83%
“…In addition, intrafractional motion may have occurred, because the shoulder could not be immobilized with the thermoplastic shell. Zhuang et al reported that a setup error as small as 1 mm and 0.5° could be detected using an anthropomorphic phantom with the PerFRACTION software . As described above, the lack of a setup error evaluation was a limitation of our study.…”
Section: Discussionmentioning
confidence: 83%
“…PerFRACTION™ reliably identified experimentally introduced errors and estimated their impact. With this initial validation result and recent publications,[11121314] we have introduced PerFRACTION™ into daily clinical practice to further validate this software program using clinical data.…”
Section: Resultsmentioning
confidence: 96%
“…reported that EPID based measurements using Per-FRACTION software could detect setup errors as small as 1 mm. 10 A number of investigators have shown a linear relation between EPID response and dose, and the EPID measurements have been increasingly introduced for daily pretreatment verifications owing to its simple procedure (without need for setting detectors). [18][19][20] However, the presence of the support arm may affect the EPID measurements because the backscattered radiation dose can be occurred from the metallic parts in the support arm.…”
Section: Discussionmentioning
confidence: 99%
“…The detector has an active area of 400 mm × 400 mm with a small pixel size of 0.34 mm, and the integrated dose images were acquired for each arc beam at the source to detector distance of 170 cm without any obstructions. The acquired images were automatically retrieved to a commercial dose verification software (PerFRACTION version 2.0.4, Sun Nuclear Corporation, Melborne, FL) 10,11 and were compared with the corresponding expected dose maps, which was generated from the DICOM files of treatment plan from the TPS.…”
Section: Dosimetric Verificationmentioning
confidence: 99%