2014
DOI: 10.1088/0031-9155/59/15/4065
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity recovery for the AX-PET prototype using inter-crystal scattering events

Abstract: The development of novel detection devices and systems such as the AX-positron emission tomography (PET) demonstrator often introduce or increase the measurement of atypical coincidence events such as inter-crystal scattering (ICS). In more standard systems, ICS events often go undetected and the small measured fraction may be ignored. As the measured quantity of such events in the data increases, so too does the importance of considering them during image reconstruction. Generally, treatment of ICS events wil… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(23 citation statements)
references
References 17 publications
0
23
0
Order By: Relevance
“…To our knowledge, only a contemporary study 24 took into account the possibility of having different sensitivity profiles for double and IDS coincidences, while in previous works, standard normalizations were applied to datasets containing double and IDS events. 12,13 Importantly, adding incorrectly normalized data to the standard PET coincidences can adversely affect image-quality metrics such as SNR or contrast-to-noise ratio, which may further explain results found in the earlier studies 13 that utilized real data from a scanner.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…To our knowledge, only a contemporary study 24 took into account the possibility of having different sensitivity profiles for double and IDS coincidences, while in previous works, standard normalizations were applied to datasets containing double and IDS events. 12,13 Importantly, adding incorrectly normalized data to the standard PET coincidences can adversely affect image-quality metrics such as SNR or contrast-to-noise ratio, which may further explain results found in the earlier studies 13 that utilized real data from a scanner.…”
Section: Discussionmentioning
confidence: 99%
“…[21][22][23][24] In some of these studies, [21][22][23] the complete interaction sequence for each annihilation photon of IDS or intercrystal scattered events is delineated in order to select the earliest interactions and, thus, the points defining the LOR containing the original decay. In general, a Bayesian estimator based on Compton kinematics is used in an iterative reconstruction algorithm to ensure that all the interactions within each sequence are consistent with the entire dataset.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…A detailed description of the technique can be found in Ref. [4]. Images were reconstructed with and without ICS for a rat injected by 18 F, as shown in Fig.…”
Section: New Algorithms For a Novel Conceptmentioning
confidence: 99%