2020
DOI: 10.1016/j.infrared.2020.103517
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity optimization of symmetric multi-core fiber strain sensor based on mode-coupling theory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 29 publications
1
3
0
Order By: Relevance
“…The structure showed good guidance in the 1500 to 1600 nm spectral range of interest. As a result, 6 μm diameter cores with a core-to-core pitch of 18 μm were achieved, in agreement with [10]. The difference between the both lied exclusively in the arrangement of their cores.…”
Section: Sensor Design and Experimental Setupsupporting
confidence: 81%
See 1 more Smart Citation
“…The structure showed good guidance in the 1500 to 1600 nm spectral range of interest. As a result, 6 μm diameter cores with a core-to-core pitch of 18 μm were achieved, in agreement with [10]. The difference between the both lied exclusively in the arrangement of their cores.…”
Section: Sensor Design and Experimental Setupsupporting
confidence: 81%
“…1 (c). The operating principle of each sensor is based on the reduction in core diameter and core-to-core pitch with its elongation, which results in a change of the coupling coefficient and a shift of the wavelength dip in transmission spectrum [10]. In order to characterize this strain dependency, the fiber was attached to a motorized custom station equipped with two opposing clamps with a spacing that can be controlled with a minimum step of 17 nm.…”
Section: Sensor Design and Experimental Setupmentioning
confidence: 99%
“…On the one hand, the interrogation system allows for multiplexing, optimizing the spectral efficiency of the sensors, interrogating them individually and using devices with similar or even identical spectra, as they are identified by their and not by the shape of their spectra. On the other hand, MCFs provide several intrinsic advantages such as high sensitivity, ease of interrogation, possibility to design ad-hoc geometries to optimize their sensitivity for the measurement of certain parameters 36 , 37 , etc. Thus, the potential benefits of the combination of the proposed interrogation system with MCFs are of big interest for multipoint sensing systems.…”
Section: Operational Mechanism and Experimental Setupmentioning
confidence: 99%
“…2 b, which was used as sensor head in this work, when a broadband light is launched into the central core of the TCF and analyzed at its exit by a spectrometer, a series of maxima and minima appear in the spectrum. However, when the same SMF-TCF-SMF structure is interrogated in reflection 21 , 27 , 36 , 37 , the light travels back and forth through it and the normalized coupled power at the output becomes: …”
Section: Operational Mechanism and Experimental Setupmentioning
confidence: 99%