2000
DOI: 10.1002/1521-4109(200007)12:11<805::aid-elan805>3.0.co;2-x
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity of Electrochemically Nanostructured Carbon Fiber Ultramicroelectrodes in the Determination of Adenosine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
18
0

Year Published

2002
2002
2018
2018

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(19 citation statements)
references
References 21 publications
1
18
0
Order By: Relevance
“…After curing, the tip of the electrode was sanded off in a polishing wheel (Arotec, Brazil) using 600-grit silicon carbide paper (Arotec, Brazil), and finally the surface was gently polished in the polishing wheel with 0.1 mm particle size g-alumina suspension (Arotec, Brazil). Before use, the polished electrodes were sonicated 37,38 in isopropyl alcohol and in doubly distilled water during 5 min in each solvent. The response of the polished electrodes was tested by cyclic voltammetry with 5.0 mmol L -1 potassium ferricyanide in 0.5 mol L -1 KCl solution at 50 mV s -1 .…”
Section: Electrodesmentioning
confidence: 99%
“…After curing, the tip of the electrode was sanded off in a polishing wheel (Arotec, Brazil) using 600-grit silicon carbide paper (Arotec, Brazil), and finally the surface was gently polished in the polishing wheel with 0.1 mm particle size g-alumina suspension (Arotec, Brazil). Before use, the polished electrodes were sonicated 37,38 in isopropyl alcohol and in doubly distilled water during 5 min in each solvent. The response of the polished electrodes was tested by cyclic voltammetry with 5.0 mmol L -1 potassium ferricyanide in 0.5 mol L -1 KCl solution at 50 mV s -1 .…”
Section: Electrodesmentioning
confidence: 99%
“…El-Nour prepared a highly active carbon fiber ultramicroelectrode (CFE) as sensor in the sensitive determination of adenosine under physiological conditions. 15 Oliveira-Brett used a carbon fiber microelectrode for the investigation on the electrooxidation mechanism of guanine and adenine. 16 The reduced capacitive contribution of microelectrodes makes it possible to study the electron transfer (ET) reactions of these processes by means of fast scan rate cyclic voltammetry and to establish a more sensitive detection method by differential pulse voltammetry.…”
Section: Introductionmentioning
confidence: 99%
“…The new method of FSV determinations of adenosine at the new CFEs is sensitive. 12,13 It has been postulated that the CFE surface nanostructure, of the CFEs that were fabricated by the new procedure, produced during the ECP of the electrode and maintained by the method of FSV signal acquisition, contributes to the high sensitivity in the determinations of adenosine. 12 High sensitivity is important in the determination of adenosine in biological samples because of the transient nature of the adenosine signal, which reaches micromolar concentrations during physiological stress.…”
Section: Introductionmentioning
confidence: 99%