1974
DOI: 10.1177/22.2.80
|View full text |Cite
|
Sign up to set email alerts
|

SENSITIVITY IN ELECTRON MICROSCOPE AUTORADIOGRAPHY FOR 125I

Abstract: Sensitivity in electron microscope autoradiography was determined for 125!. Values are given using Ilford L4 and Kodak NTE emulsions combined with different developers. The extent of self-absorption as a function of section thickness and heavy metal staining and the effect of radiation dose (dose dependence) were assessed. It was found that the overall efficiency for 125! was better than that for tritium and that, as is the case with tritium, there is a distinct "dose dependence" especially when Microdol X is … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
51
1

Year Published

1976
1976
1987
1987

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 59 publications
(55 citation statements)
references
References 0 publications
3
51
1
Order By: Relevance
“…Doing so entails a loss in grain yield and no significant gain in resolution. A fine-grained emulsion like Kodak NTE2 gains 38% in resolution and is recommended since specific activities with 1251 are high as is sensitivity (6). As shown in this study, resolution of ~500 A is thereby attainable-the best yet for EM autoradiography.…”
Section: Reassessment Of Critical Parameters Affecting Em Autoradiogrmentioning
confidence: 76%
See 3 more Smart Citations
“…Doing so entails a loss in grain yield and no significant gain in resolution. A fine-grained emulsion like Kodak NTE2 gains 38% in resolution and is recommended since specific activities with 1251 are high as is sensitivity (6). As shown in this study, resolution of ~500 A is thereby attainable-the best yet for EM autoradiography.…”
Section: Reassessment Of Critical Parameters Affecting Em Autoradiogrmentioning
confidence: 76%
“…The albumin was applied with a medicine dropper onto a slide held horizontally and was then drained vertically. This procedure was similar to that used for making the sensitivity specimen described previously (6). Then, to render the film insoluble in water, it was exposed to paraformaldehyde vapor for 10 min.…”
Section: Resolution Specimensmentioning
confidence: 99%
See 2 more Smart Citations
“…The determination of grain density (grains/micrometer2) and of the length of primary and secondary clefts and the thickened postsynaptic membrane were determined by previously published morphometric procedures (15,16). Histograms of the grain distribution in motor endplates were constructed for the various control and experimental groups.…”
Section: Analysis Of Autoradiogramsmentioning
confidence: 99%