2015
DOI: 10.1007/s00216-015-8771-6
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive gluten determination in gluten-free foods by an electrochemical aptamer-based assay

Abstract: Enzyme-immune assays are currently the methods of choice for gluten control in foods labelled as "gluten free", providing a mechanism for assessing food safety for consumption by coeliac and other allergic patients. However, their limitations, many of them associated to the reactivity of the different antibodies used and their degree of specificity, have prevented the establishment of a standardized method of analysis. We explore new methods for quantitatively determine gluten content in foods based on the use… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
27
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
3
3
1

Relationship

1
6

Authors

Journals

citations
Cited by 44 publications
(30 citation statements)
references
References 28 publications
3
27
0
Order By: Relevance
“…Immobilization of the aptamer was found to be more deleterious in terms of affinity than the immobilization of the 33-mer peptide [17], so the latter was anchored through streptavidin-biotin interaction to the electrode surface. Among the aptamers raised against 33-mer [16], Gli 4 was selected because of its highest affinity and good performance in competitive magnetoassays [18]. Likewise, biotin was used as a tag for subsequent enzymatic labelling.…”
Section: Resultsmentioning
confidence: 99%
“…Immobilization of the aptamer was found to be more deleterious in terms of affinity than the immobilization of the 33-mer peptide [17], so the latter was anchored through streptavidin-biotin interaction to the electrode surface. Among the aptamers raised against 33-mer [16], Gli 4 was selected because of its highest affinity and good performance in competitive magnetoassays [18]. Likewise, biotin was used as a tag for subsequent enzymatic labelling.…”
Section: Resultsmentioning
confidence: 99%
“…In the same context, Tran et al have successfully designed specific aptamers strands against food allergens including lysozyme [56] and Ara h 1 [59]. Several aptamer sequences for gluten were selected by two research groups, by taking as analytical target either the intact gliadin protein [60] or the immunodominant toxic 33-mer peptide [61]. Despite of the progress in the field of aptasensing, very few reports are available in literature for aptasensing detection of food allergens.…”
Section: Design Of Sensitive Biosensors For Allergen Based On Scrementioning
confidence: 99%
“…This method, however, has the disadvantage of low stability caused by desorption from the surface. The commonly used immobilization techniques to obtain a stable and active aptamer-functionalized surface include covalent coupling [39,42] click chemistry [43] and avidin-biotin affinity [61]. Chemisorption of the thiolated aptamer onto a gold electrode surface [52] could be envisaged as well, similarly to aptasensors for other analytes relevant for food safety.…”
Section: Design Of Sensitive Biosensors For Allergen Based On Scrementioning
confidence: 99%
See 2 more Smart Citations