1985
DOI: 10.1111/j.1398-9995.1985.tb00219.x
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive Glass Microfibre‐Based Histamine Analysis for Allergy Testing in Washed Blood Cells

Abstract: The new microfibre method for allergy testing is based on basophil histamine release after challenge with suspected allergens in samples of 50 microliter washed blood cells. Released histamine is bound to microfibres and measured after removal of interfering substances by washing. The microfibre method was compared with the conventional leukocyte histamine release assay in 18 allergic patients tested with 10 different allergens. It was found that the same individuals responded with histamine release to the sam… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
34
0

Year Published

1988
1988
2012
2012

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 103 publications
(34 citation statements)
references
References 12 publications
0
34
0
Order By: Relevance
“…Fibers were inserted through 2 cm of the cutis of the volar forearm under local anesthesia (Emla, AstraZeneca) and perfused with sterile isotonic saline solution at a rate of 3.0 µl/min. Histamine concentrations were determined by fluorescence spectroscopy [9] in the microdialysis eluate obtained consecutively for 24 (12 × 2) min each at baseline, after cold stimulation (ice cube) and after intracutaneous injection of 50 µg of codeine 1 mm away from the fiber. …”
Section: Methodsmentioning
confidence: 99%
“…Fibers were inserted through 2 cm of the cutis of the volar forearm under local anesthesia (Emla, AstraZeneca) and perfused with sterile isotonic saline solution at a rate of 3.0 µl/min. Histamine concentrations were determined by fluorescence spectroscopy [9] in the microdialysis eluate obtained consecutively for 24 (12 × 2) min each at baseline, after cold stimulation (ice cube) and after intracutaneous injection of 50 µg of codeine 1 mm away from the fiber. …”
Section: Methodsmentioning
confidence: 99%
“…After pas sive sensitization, this dependence disappeared and no significant difference in the maximum anti-IgE-in- duced HR was seen between the three plgE levels. Furthermore, the dose response to anti-IgE became similar to that observed in adult blood, exhibiting the well-desribed bell shape [13,14] with maximum re lease occurring at a tenfold lower concentration of anti-lgE than before passive sensitization.…”
Section: Ige-mediated Histamine Releasementioning
confidence: 96%
“…Only sam ples containing more than 8.5 ml of blood were used for the passive sensitization and pharmacological modulation experiments (n = 86). Histamine Release Determination HR was measured by a fluorometric method based on the affin ity of histamine for ground glass microfibers, modified from that first described by Stahl Skov et al [13,14].…”
Section: Blood Samplingmentioning
confidence: 99%
See 1 more Smart Citation
“…A previously described micromethod was applied [15]. The provoc ative concentration was determined as the concentration giving half the maximum histamine release.…”
Section: Histamine Release Assaymentioning
confidence: 99%