2013
DOI: 10.1016/j.talanta.2013.04.002
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive determination of paraquat by square wave anodic stripping voltammetry with chitin modified carbon paste electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
21
0
1

Year Published

2013
2013
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(24 citation statements)
references
References 31 publications
2
21
0
1
Order By: Relevance
“…The optimum pH range was found between 7.14 and 8.71, with a maximum response at pH 7.50. The sensitivity decrease in acidic solution was accompanied with a decrease in reduction peaks, which is in close agreement with published results [37].…”
Section: Effect Of Measurement Conditions On Square Wave Responsessupporting
confidence: 93%
“…The optimum pH range was found between 7.14 and 8.71, with a maximum response at pH 7.50. The sensitivity decrease in acidic solution was accompanied with a decrease in reduction peaks, which is in close agreement with published results [37].…”
Section: Effect Of Measurement Conditions On Square Wave Responsessupporting
confidence: 93%
“…In the recent years, the SW voltammetry has emerged as a viable and cheap alternative to the expensive and time-consuming techniques (such as chromatography, or spectrophotometry, for example) for the determination of inorganic and biologically important compounds. The simple working set-up, the quick time of performing the measurements, the different modes that can be applied, together with its sensitivity, make the SWV a technique of choice for quantification of important classes of compounds such as proteins [82], vitamins [83], phenols [84][85][86][87][88], benzoquinones [89], pesticides, herbicides and fungicides [90][91][92][93][94][95][96][97][98], alkaloids [99], terpenoids [100], heavy metals [101][102][103][104][105][106][107][108][109][110][111][112][113][114][115][116], and drugs [117,118]. One of the most valuable ability of SWV is its application for simultaneous determination of compounds with similar structures present in various pharmaceutical and physiological samples.…”
Section: Analytical and Biochemical Applications Of Square-wave Voltamentioning
confidence: 99%
“…The maximum peak current was found at E acc =−0.5 V for MSM on the HMDE, indicating maximum accumulation of MSM on the surface of HMDE at this potential. 24,25) The effect of the initial potential, E i on MSM was inspected in a BR buffer at pH 2.0 by observing the effects of E i on the peak current. Fig.…”
Section: Effect Of Operating Parametersmentioning
confidence: 99%