Sensitive determination of anticancer drug imatinib in spiked human urine samples by differential pulse voltammetry on anodically pretreated boron-doped diamond electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
25
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 73 publications
(26 citation statements)
references
References 52 publications
1
25
0
Order By: Relevance
“…A cyclic voltammogram without linezolid was also showed in the graphs for comparison. The absence of any peak in the cathodic direction indicates that the oxidation process on the PG and CP electrodes of the linezolid molecule is not a reversible reaction . When the voltammograms of solutions containing 30 μg mL −1 linezolid were compared, it was observed that linezolid yielded an anodic oxidation peak (Ia) of 8.977 μA at +0.912 V at pH 4.0 and 3.799 μA at +0.865 V at pH 7.0 for PG and CP electrodes, respectively (Figure a‐b).…”
Section: Resultsmentioning
confidence: 99%
“…A cyclic voltammogram without linezolid was also showed in the graphs for comparison. The absence of any peak in the cathodic direction indicates that the oxidation process on the PG and CP electrodes of the linezolid molecule is not a reversible reaction . When the voltammograms of solutions containing 30 μg mL −1 linezolid were compared, it was observed that linezolid yielded an anodic oxidation peak (Ia) of 8.977 μA at +0.912 V at pH 4.0 and 3.799 μA at +0.865 V at pH 7.0 for PG and CP electrodes, respectively (Figure a‐b).…”
Section: Resultsmentioning
confidence: 99%
“…One appealing property of BDDEs is their resistance to fouling, as called to attention in the introduction of section 3. In this regard, Brycht et al [110] reported that an APT-BDDE had a higher resistance to surface fouling than a CPT-BDDE when used in the determination of the anticancer drug imatinib. As a consequence, better repeatability of the voltammetric measurements was attained using the APT-BDDE.…”
Section: Discussionmentioning
confidence: 99%
“…Imatinib (IMA), a new generation of anticancer drug, was quantified by Brycht and coauthors using DPV . The authors used BR buffer pH 2.0 on BDD electrodes (doping level of 1000 ppm).…”
Section: Electroanalysis Of Pharmaceuticalsmentioning