2022
DOI: 10.3389/fcimb.2022.949514
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive and visual identification of Chlamydia trachomatis using multiple cross displacement amplification integrated with a gold nanoparticle-based lateral flow biosensor for point-of-care use

Abstract: Chlamydia trachomatis is the leading cause of bacterial sexually transmitted infection (STI) and remains a major public health challenge, especially in less-developed regions. Establishing a rapid, inexpensive, and easy-to-interpret point-of-care (POC) testing system for C. trachomatis could be critical for its treatment and limiting further transmission. Here, we devised a novel approach termed a multiple cross displacement amplification integrated with gold nanoparticle-based lateral flow biosensor (MCDA-AuN… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 36 publications
0
5
0
Order By: Relevance
“…However, the two former approaches need expensive facilities and are not suitable for a POC diagnostic platform. The L‐HNB method was visual and equipment‐free, but need more amplification time for detection of the LoD (Figure 6B,C), and the visual result was ambiguous when the amplicons were low 23,25 . Our AuNPs‐LFB strip was convenient operation and inexpensive (approximately US$2.0 per test).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, the two former approaches need expensive facilities and are not suitable for a POC diagnostic platform. The L‐HNB method was visual and equipment‐free, but need more amplification time for detection of the LoD (Figure 6B,C), and the visual result was ambiguous when the amplicons were low 23,25 . Our AuNPs‐LFB strip was convenient operation and inexpensive (approximately US$2.0 per test).…”
Section: Discussionmentioning
confidence: 99%
“…The HCV‐positive samples were also identified with Sanger sequencing (Dian Medical Laboratory Center Co. Ltd.). Online statistical software MedCalc (http://www.medcalc.org/calc/diagnostic_test.php) was used to analyze the conventional HCV‐RT‐qPCR and HCV‐RT‐LAMP‐AuNPs‐LFB methods 23 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Novel POC test systems using loop-mediated amplification have increasingly been introduced in the last years for different infectious agents, e.g. for malaria in pregnant women [ 8 ], SARS-CoV-2 [ 9 ], or C. trachomatis [ 10 ]. With a rising incidence of STI in selected populations the need for POC tests has increased for this indication with accuracy and reasonable pricing being the main factors required for implementation [ 11 ].…”
Section: Discussionmentioning
confidence: 99%
“…Novel POC test systems using loop-mediated ampli cation have increasingly been introduced in the last years for different infectious agents, e.g. for malaria in pregnant women [5], SARS-CoV-2 [6], or C. trachomatis [7]. With a rising incidence of STI the need of POC tests has increased for this indication with accuracy and reasonable pricing being main factors required for implementation [8].…”
Section: Discussionmentioning
confidence: 99%