Sensitive and Real-Time Method for Evaluating Corneal Barrier Considering Tear Flow

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
18
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(19 citation statements)
references
References 19 publications
1
18
0
Order By: Relevance
“…Until recently, absorption studies were commonly performed in laboratory animals or in excised rabbit, bovine, or porcine corneas mounted in diffusion chambers, such as Franz diffusion cells or Ussing chambers. 9,21,22 Not only are these studies labor intensive, expensive, poorly standardized, and impractical for large-scale and rapid drug formulation screening; they also exhibit interspecies variation due to the differences in anatomy and morphology of the eyes. 9,23 Pig eyes are structurally the most similar to human eyes in terms of the size, corneal thickness, and the presence of Bowman's layer.…”
mentioning
confidence: 99%
“…Until recently, absorption studies were commonly performed in laboratory animals or in excised rabbit, bovine, or porcine corneas mounted in diffusion chambers, such as Franz diffusion cells or Ussing chambers. 9,21,22 Not only are these studies labor intensive, expensive, poorly standardized, and impractical for large-scale and rapid drug formulation screening; they also exhibit interspecies variation due to the differences in anatomy and morphology of the eyes. 9,23 Pig eyes are structurally the most similar to human eyes in terms of the size, corneal thickness, and the presence of Bowman's layer.…”
mentioning
confidence: 99%
“…19 The lower corneal TER values are indicative of the penetration of greater amounts of electrical current through the damaged superficial cells and tight junctions that exist in the epithelium. 6,7,14,15,24 In addition, these electrical changes can be measured continuously and quantitatively. Therefore, measurement of corneal TER is a suitable method for evaluating corneal permeability and irritancy.…”
Section: Discussionmentioning
confidence: 99%
“…16,17 We previously developed that new electrophysiological method mimicking tear flow in which the precorneal solution was exchanged for a buffer with a peristaltic pump at the rate of human tear flow and excised rabbit corneas. 14 The method for evaluating eyedrop-induced corneal toxicity considering tear flow is invaluable, as tears dilute the eyedrops immediately after instillation. By using this method, we were able to determine that the TER of the excised rabbit corneas was *1 k-ohm$cm 2 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations