“…Langmuir adsorption isotherm is stated as, The quantity of the constant values is taken from the available literature [32,33]. Additionally, the free energy of adsorption (∆G sorption ) was calculated as well at -6.3 ±0.81 kcal mol -1 , which is a comparable value with the previous analysis reported for a favourable adsorption process [34].…”
Section: Immunoassay Analysis Of the Biosensormentioning
confidence: 73%
“…The results are given in Table 1 and the experimentally measured data is in good agreement with the theoretical values. The adsorption parameters to understand the CEA interaction with the anti-CEA at the bioreceptor interface can be evaluated through Langmuir and Freundlich isotherms, [32,33].…”
Section: Immunoassay Analysis Of the Biosensormentioning
Highly stable, love-mode surface acoustic wave biosensor using Au nanoparticle-MoS2-rGO nano-cluster doped polyimide nanocomposite for the selective detection of carcinoembryonic antigen. Materials Chemistry and Physics, 246. p. 122800.
“…Langmuir adsorption isotherm is stated as, The quantity of the constant values is taken from the available literature [32,33]. Additionally, the free energy of adsorption (∆G sorption ) was calculated as well at -6.3 ±0.81 kcal mol -1 , which is a comparable value with the previous analysis reported for a favourable adsorption process [34].…”
Section: Immunoassay Analysis Of the Biosensormentioning
confidence: 73%
“…The results are given in Table 1 and the experimentally measured data is in good agreement with the theoretical values. The adsorption parameters to understand the CEA interaction with the anti-CEA at the bioreceptor interface can be evaluated through Langmuir and Freundlich isotherms, [32,33].…”
Section: Immunoassay Analysis Of the Biosensormentioning
Highly stable, love-mode surface acoustic wave biosensor using Au nanoparticle-MoS2-rGO nano-cluster doped polyimide nanocomposite for the selective detection of carcinoembryonic antigen. Materials Chemistry and Physics, 246. p. 122800.
“…The measured data of the biosensor show good agreements with the theoretical values and the results are listed in table 2. The sorption equilibrium was studied to understand the favourability of antigen -antibody interaction using Langmuir and Freundlich sorption kinetics [27,28]. According to Langmuir sorption isotherm,…”
Section: Immunoassay Response Of Au Coated Saw Biosensormentioning
confidence: 99%
“…where Ce is the equilibrium concentration (mg/L) of CEA stock solutions, qe is the equilibrium sorption capacity (mg mg −1 );, the constant q0 indicates the real sorption capacity (mg mg−1) of the biosensor and b is related to the energy of sorption (L mmol −1 ). The constant values have been adopted from the previously published works [27,28] and the isotherm curves is plotted as Ce/qe v/s Ce, as shown in figure 9. The date points can be fit into a straight line which indicates that the sorption process during the immunoassay experiment in the present study follows Langmuir kinetics.…”
Section: Immunoassay Response Of Au Coated Saw Biosensormentioning
A love-mode surface acoustic wave (SAW) biosensor based on ST-cut quartz was developed for highly selective and label-free detection of carcinoembryonic antigen (CEA).The delay line area of an interdigital transducer (IDT) based SAW device was coated with gold and then chemically modified through thioglycolic acid-EDC/NHS reaction mechanism. A self-assembled monolayer of anti-CEA was further immobilized on the bioreceptors through the coupling layer. The biosensing capability of the SAW device was evaluated using solutions of CEA with various concentrations and limit of detection was obtained at 0.31 ng/ml of CEA, which is better than the results reported by the literatures available for CEA detection using SAW device. The real-time detection capability of the biosensor was evaluated using clinical serum samples and selectivity was evaluated using mixed solutions of CEA with other common tumor marking proteins. Long-term stability of the biosensor was also evaluated over a period of 30 days and the biosensing performance has shown only 8% decrease in performance within the whole period. The binding of CEA onto the bioreceptor was evaluated through Langmuir and Freundlich sorption isotherm kinetic studies as well.
“…Calixarenes are capable to form Host-Guest complexes in the gas phase, in solutions, in the crystalline state and in two-dimensional phases -thin films [7]. Chemosensors based on calixarene thin films have been used to create devices capable of recognizing cations, anions and neutral organic molecules in solutions (artificial tongue) or in the air (artificial nose) [8][9][10][11][12][13].…”
This work reports on the investigation of sensory properties of thiacalix[4]arene molecules towards volatile halogen-aromatic compounds. Experiments were carried out using the 8-channel sensory system based on Quartz Crystal Microbalance (QCM) technique. Kinetic responses, concentration dependences and detection limit have been obtained. It has been shown that interaction of the sensitive layer with the analyte molecules is substantially defined by the chemical structure of thiacalix[4]arene. Thus, thiacalix[4]arene materials considered in this paper are of great interest for application in the sensory systems of "Electronic Nose" type.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.