2001
DOI: 10.1093/jaoac/84.6.1846
|View full text |Cite
|
Sign up to set email alerts
|

Semiautomatic Flow-Injection Method for Determination of Volatile Acidity in Wines

Abstract: A flow-injection (FI) method based on analytical pervaporation was assessed for its routine use in the determination of volatile acidity in winery laboratories. The new method was compared with both the official method and the Mathieu method, which is most often used in Spanish wineries, by testing 30 different wines, including young and aged, and sweet and dry wines from Montilla-Moriles appellation d'origine. The robustness of the new method was established, and then all 3 methods were studied in terms of ra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 6 publications
1
6
0
Order By: Relevance
“…The developed novel, automated flow-based system with spectrophotometric detection for determination of VA integrates procedures of steam distillation to separate volatile acids and titration for their determination. Comparing with other methods reported in the literature, they usually use pervaporation or gas diffusion for separating volatile acids [21][22][23][24][25][26][27][28].…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…The developed novel, automated flow-based system with spectrophotometric detection for determination of VA integrates procedures of steam distillation to separate volatile acids and titration for their determination. Comparing with other methods reported in the literature, they usually use pervaporation or gas diffusion for separating volatile acids [21][22][23][24][25][26][27][28].…”
Section: Discussionmentioning
confidence: 99%
“…It was found that using 28 mL of water for SD resulted in collecting about 25 mL of distillate, therefore this volume of the sample after distillation was obtained in further studies. These volumes ensured that all the analyte was transferred to the distillate, hence, unlike other methods [21][22][23][24][25][26][27][28], there was no need to calibrate the system. There was no significant difference observed between the results obtained for different sample volumes, but due to the low relative error of the obtained results and better precision, sample volume of 6 mL was selected.…”
Section: Step Sv I Position Sp I Flow Ratementioning