2006
DOI: 10.1007/s10334-006-0030-6
|View full text |Cite
|
Sign up to set email alerts
|

Semiautomatic Analysis of Phase Contrast Magnetic Resonance Imaging of Cerebrospinal Fluid Flow through the Aqueduct of Sylvius

Abstract: Semiautomatic measurements (seed method with half moon background and aliasing correction) allow a generalization of the calculus of flow parameters with great consistency and independency of the operator.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
20
0
2

Year Published

2010
2010
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 29 publications
(22 citation statements)
references
References 28 publications
0
20
0
2
Order By: Relevance
“…Regrettably, in many other studies where CSF movement in the aqueduct of Sylvius has been examined in physiological conditions by different MR imaging techniques, the obtained results did not allow presentation of the rate of CSF formation (V f ) neither from reported flow values nor from the CSF velocity (Baledent et al, 2006;Barkhof et al, 1994;Florez et al, 2006;Kim et al, 1999;Lee et al, 2004;Luetmer et al, 2002;Mase et al, 1998;Schroeder et al, 2000;Scollato et al, 2008;Stahlberg et al, 1989). The reason for this lies in the fact that attempts have been made to diagnose pathologic changes by means of other, more easily measurable hydrodynamic parameters in the aqueduct of Sylvius (see above).…”
Section: Magnetic Resonance Imaging Methodsmentioning
confidence: 96%
See 2 more Smart Citations
“…Regrettably, in many other studies where CSF movement in the aqueduct of Sylvius has been examined in physiological conditions by different MR imaging techniques, the obtained results did not allow presentation of the rate of CSF formation (V f ) neither from reported flow values nor from the CSF velocity (Baledent et al, 2006;Barkhof et al, 1994;Florez et al, 2006;Kim et al, 1999;Lee et al, 2004;Luetmer et al, 2002;Mase et al, 1998;Schroeder et al, 2000;Scollato et al, 2008;Stahlberg et al, 1989). The reason for this lies in the fact that attempts have been made to diagnose pathologic changes by means of other, more easily measurable hydrodynamic parameters in the aqueduct of Sylvius (see above).…”
Section: Magnetic Resonance Imaging Methodsmentioning
confidence: 96%
“…Because the aqueduct has a constant diameter over a certain length, a rather constant flow pattern is present as opposed to, for example, the foramina of Monro where irregular flow patterns may be encountered. Cardiac cycle-related cerebral blood volume variations produce bidirectional oscillatory movement of CSF within the aqueduct (Barkhof et al, 1994;Florez et al, 2006;Greitz et al, 1993;Lee et al, 2004;Luetmer et al, 2002;Ohara et al, 1988). During systole, the net inflow of blood increases the intracranial volume and induces craniocaudal (systolic) CSF movement.…”
Section: Magnetic Resonance Imaging Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…CSF flow data were processed using GE ReportCard software (v. 3.6; General Electric) and peak positive and negative velocities for each phase were recorded. Two of the ReportCard software limitations are: using a manually, operator-dependent segmented ROI in quantifying flow (which results in large variability of the flow rates measured (7,15)); and using this single, stationary ROI for all phases of the cine PC acquisition. Consequently, a semiautomated Minimum Area Contour Change (MACC) program was designed to correct the ROIs for each phase, as previously described (11,14).…”
Section: Cine Phase Contrast Image Analysismentioning
confidence: 99%
“…Cine phase contrast MRI has been previously used for CSF flow quantification in healthy controls (HC), patients with hydrocephalus, stroke patients, the elderly, etc (6)(7)(8)(9).…”
mentioning