Semi-automated volumetric analysis of lymph node metastases in patients with malignant melanoma stage III/IV-A feasibility study

Abstract: Therapy monitoring in oncological patient care requires accurate and reliable imaging and post-processing methods. RECIST criteria are the current standard, with inherent disadvantages. The aim of this study was to investigate the feasibility of semi-automated volumetric analysis of lymph node metastases in patients with malignant melanoma compared to manual volumetric analysis and RECIST. Multislice CT was performed in 47 patients, covering the chest, abdomen and pelvis. In total, 227 suspicious, enlarged lym… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
45
0

Year Published

2008
2008
2016
2016

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 67 publications
(46 citation statements)
references
References 19 publications
(20 reference statements)
1
45
0
Order By: Relevance
“…However, it is generally felt that for assessment of early response, particularly in risk-adapted therapeutic trials, it is preferable to refer to a background tissue (such as the liver) with a higher level of uptake than that of current international criteria that were designed for end-of-treatment evaluation. 13 As recently shown, the reproducibility of lymph node measurements is poorest below 20 mm, which leads to major discrepancies in FDG-PET interpretation 14 as the reference background changes. In 2009, an international workshop on interim FDG-PET 15 took place to reach a consensus on criteria for interim FDG-PET scans.…”
Section: Interpretation Of Pet Scansmentioning
confidence: 99%
“…However, it is generally felt that for assessment of early response, particularly in risk-adapted therapeutic trials, it is preferable to refer to a background tissue (such as the liver) with a higher level of uptake than that of current international criteria that were designed for end-of-treatment evaluation. 13 As recently shown, the reproducibility of lymph node measurements is poorest below 20 mm, which leads to major discrepancies in FDG-PET interpretation 14 as the reference background changes. In 2009, an international workshop on interim FDG-PET 15 took place to reach a consensus on criteria for interim FDG-PET scans.…”
Section: Interpretation Of Pet Scansmentioning
confidence: 99%
“…All volume and bi-dimensional measurements were therefore converted to diameters as recently published by different groups [16,19,27]. These effec- tive diameters were measured in mm and defined as volumeequivalent and area-equivalent diameters.…”
Section: Response Assessment Response Criteriamentioning
confidence: 99%
“…In the past decade, semi-automatic tumor segmentation and measurement tools have demonstrated their technical feasibility with regard to lung nodule and liver lesion segmentation [13, 20, 32 -34]. Recent studies specifically addressed the aspects of reproducibility and variability between different readers in the semi-automated segmentation of tumor-affected lymph nodes, and found inter-user differences to be reduced by a factor of approximately 1.4 to 3.0 compared to the manual approach [16,19,35]. These feasibility studies are limited by their lack of data on follow-up examinations, whereby inter-user differences could be aggravated, e. g. due to variable lymph node orientation caused by shrinkage.…”
mentioning
confidence: 99%
“…Automated volume segmentation has been demonstrated to be accurate in the measurement of volume of organs, tumors, lymph nodes, and pulmonary nodules using various imaging modalities. [8][9][10][11][12][13][14][15] Volume segmentation has specifically been used to accurately determine knee effusion volumes based on T2 MRI images with good interobserver reliability. 3,4 Similar technology has been used to determine intra-articular fluid volume of the first metatarsal phalangeal joint.…”
Section: Introductionmentioning
confidence: 99%