2000
DOI: 10.1016/s0167-6105(00)00024-6
|View full text |Cite
|
Sign up to set email alerts
|

Semi-active Tuned Mass Damper control strategy for wind-excited structures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
24
0
1

Year Published

2007
2007
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(25 citation statements)
references
References 4 publications
0
24
0
1
Order By: Relevance
“…Another limitation of a TMD is the size of the tuned absorber mass. In an attempt to increase the performance of the TMD without incurring the problems noted above, active and semi-active TMD (ATMD and SATMD) systems have been proposed [4][5][6][7]. To overcome the limitation of the TMD mass, various seismic isolation concepts using TMD related principles have been extended to convert a structural system into a TMD system by specially designing the structural system [8][9][10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…Another limitation of a TMD is the size of the tuned absorber mass. In an attempt to increase the performance of the TMD without incurring the problems noted above, active and semi-active TMD (ATMD and SATMD) systems have been proposed [4][5][6][7]. To overcome the limitation of the TMD mass, various seismic isolation concepts using TMD related principles have been extended to convert a structural system into a TMD system by specially designing the structural system [8][9][10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…In addition to passive TMD, active TMD (Chang and Soong, 1980;Soong, 1990) and semi-active TMD (Hrovat et al, 1982;Abe, 1996;Abe and Igusa, 1996;Ricciardellia et al, 2000;Yalla et al, 2001;Nagarajaiah and Varadarajan, 2005) have been proposed. Although active and semi active TMDs possess higher performance in vibration suppression, they must have control algorithms, sensors, external power and higher maintenance cost.…”
Section: Introductionmentioning
confidence: 99%
“…Indeed, Chang (1999) and Ricciardelli et al (2000) presented a generalized method to optimally design TMD and semi-active TMD to reduce wind vibration in structures modeled as SDoF systems, but they defined the wind load as WN. In that sense this paper presents a better representation of the wind load applied to a simple structure modeled as a SDoF system.…”
Section: Discussionmentioning
confidence: 99%
“…In literature these kinds of loads have been modeled as stochastic processes. In particular, the earthquake load has often been modeled as stationary WN (Chang, 1999) or filtered stationary WN (Marano et al, 2007), while the wind load has been modeled as a superposition of the mean wind speed and a fluctuating part described by a zero-mean stationary Gaussian random field characterized by a specific spectrum, such as the Kaimal-Simiu spectrum (Ricciardelli et al, 2000). In Colwell and Basu (2009) a combination of the Kaimal spectrum for the wind load and the JONSWAP (JOint North Sea WAve Project) spectrum for the ocean waves excitation has been used for the optimum design of a passive damper applied to an offshore structure.…”
Section: Introductionmentioning
confidence: 99%