2014
DOI: 10.1109/tpel.2013.2258684
|View full text |Cite
|
Sign up to set email alerts
|

Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
82
0
3

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 825 publications
(126 citation statements)
references
References 26 publications
0
82
0
3
Order By: Relevance
“…Moreover, GSC has little influence on SSR stability, therefore the analysis of GSC will be neglected in the following [19,23,24]. (5) where Isdq and Irdq are the stator and rotor current respectively, Usdq and Urdq are the stator and rotor voltage respectively, ψsdq, ψrdq and ψmdq are the stator, rotor and air-gap flux respectively, Lm, Ls and Lr are the mutual, stator and rotor inductance, in which Ls = Lm + Lsσ, Lr = Lm + Lrσ, Lsσ and Lrσ are the stator and rotor self-inductance respectively, ω is the SRF angular frequency, ωs is the slip angular frequency, ωs = ω − ωr, ωr is the rotor angular frequency. All variables are referenced to the stator.…”
Section: Vsg Control For Dfigmentioning
confidence: 99%
See 2 more Smart Citations
“…Moreover, GSC has little influence on SSR stability, therefore the analysis of GSC will be neglected in the following [19,23,24]. (5) where Isdq and Irdq are the stator and rotor current respectively, Usdq and Urdq are the stator and rotor voltage respectively, ψsdq, ψrdq and ψmdq are the stator, rotor and air-gap flux respectively, Lm, Ls and Lr are the mutual, stator and rotor inductance, in which Ls = Lm + Lsσ, Lr = Lm + Lrσ, Lsσ and Lrσ are the stator and rotor self-inductance respectively, ω is the SRF angular frequency, ωs is the slip angular frequency, ωs = ω − ωr, ωr is the rotor angular frequency. All variables are referenced to the stator.…”
Section: Vsg Control For Dfigmentioning
confidence: 99%
“…It is necessary to enhance the ability of WPGS to support power systems like conventional SGs. Based on this consideration, the virtual synchronous generator (VSG) control is proposed [4,5].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…These regulators are designed to emulate the behavior of classical synchronous generators with power converters associated to DG, ESSs, and loads connected to microgrids. In the literature, these techniques have been widely employed for diferent applications and are also known as virtual synchronous machines (VSMs) or synchronverters [8][9][10][11][12][13][14][15]. Following the main ac grid coniguration-where synchronous generators are directly connected-most of these techniques are usually employed for devices connected to ac microgrids.…”
Section: Lower-level Control Operation Modesmentioning
confidence: 99%
“…In this control method, the phase and magnitude of the load voltage were matched to the grid voltage, and there was no distortion of the load voltage and current when transferring from islanded mode to grid-connected mode. As the PLL measurement accuracy is often dependent on a parameter design, a synchronization method based on virtual impedance was proposed in [13]. This method did not require a PLL.…”
Section: Introductionmentioning
confidence: 99%