2016
DOI: 10.1088/1742-6596/773/1/012103
|View full text |Cite
|
Sign up to set email alerts
|

Self-Powered Adaptive Switched Architecture Storage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
2
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 6 publications
0
11
0
Order By: Relevance
“…The total 8% losses are distributed over two categories: 2% related to the control logic, 6% to switches and ultra-capacitors (self-discharge current). This energy efficiency performance value favorably compares to the architecture with 4-UCs [1] (91%) and to the one described in [3] (88%), which are both much more complex.…”
Section: Comparison Of Experimental Resultsmentioning
confidence: 78%
See 2 more Smart Citations
“…The total 8% losses are distributed over two categories: 2% related to the control logic, 6% to switches and ultra-capacitors (self-discharge current). This energy efficiency performance value favorably compares to the architecture with 4-UCs [1] (91%) and to the one described in [3] (88%), which are both much more complex.…”
Section: Comparison Of Experimental Resultsmentioning
confidence: 78%
“…A self-adaptive storage architecture consisting of 4 ultra-capacitors was already proposed to address these constraints [1]. This structure is based on reconfiguring the storage elements from all in-series to all in-parallel and reversely according to the availability of harvested energy and to the load consumption.…”
Section: Energy-harvesting Powered Variable Storage Topologymentioning
confidence: 99%
See 1 more Smart Citation
“…The reference architecture already proposed in a previous work [7] uses a matrix of four identical ultra-capacitors (Ci = C for I = 1, 2, 3, 4), interconnected by nine switches. As shown in Figure 2, three Schottky diodes allow a default serial structure at start-up.…”
Section: Reference Self-adaptive Switched Architecture Storage With 4mentioning
confidence: 99%
“…This concept was experimentally validated using FPGA for the control logic and external power supply for its powering [2]. The validation of the self-powering of such smart storage building block was experimentally carried out and exhibited an energy efficiency usage of 91% [3]. The next step is to build up a fully integrated smart storage block that could entirely replace a battery.…”
Section: Introductionmentioning
confidence: 99%