Self‐Moisturizing Smart Contact Lens Employing Electroosmosis

Abstract: dry eye syndrome, it is important to keep the lens moist and maintain tears between the CL and the ocular surface, which is here referred to TCO (the initial letters of tear, contact lens, and ocular). Conventional rehydration by regular eye drops, the electrical stimulation of the lacrimal gland, [17] and treatment with a punctum plug [18] will increase the total tear fluid in eye, but cannot directly address the maintenance of the amount of TCO. The only example so far of a smart CL for maintaining the TCO i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
28
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 28 publications
(32 citation statements)
references
References 44 publications
1
28
0
Order By: Relevance
“…McIlvaine buffer (pH 7.0) (Supplementary Table 2 ) was used as the electrolyte solution. Ag/AgCl (AgCl + e → Ag + Cl − ) and Ag (Ag → Ag + + e) were used for a cathode and an anode, respectively 54 . Therefore, no bubbles were observed from the electrodes during the current application.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…McIlvaine buffer (pH 7.0) (Supplementary Table 2 ) was used as the electrolyte solution. Ag/AgCl (AgCl + e → Ag + Cl − ) and Ag (Ag → Ag + + e) were used for a cathode and an anode, respectively 54 . Therefore, no bubbles were observed from the electrodes during the current application.…”
Section: Methodsmentioning
confidence: 99%
“…Electroosmotic flow (EOF) through PMN modified with charged hydrogel. By using the side-by-side Franz cell 6,54 shown in Fig. 3a, the efficiency of EOF generation (EOF strength) was evaluated to study the effect of the modification of poly-2-acrylamido-2-methylpropane sulfonate (PAMPS) into the porous structures of PMN.…”
Section: Preparation and Characterization Of Porous Microneedles (Pmn)mentioning
confidence: 99%
“…A smartphone was used as a reader to record the diffracted light signals coming out of the smart CL, which were correlated with the glucose concentrations. [ 111 ] Smart CLs can help to correct the color blindness. A rhodamine derivative was incorporated in commercial CLs to filter out specific wavelength bands (545–575 nm) to correct color vision blindness.…”
Section: Smart Clsmentioning
confidence: 99%
“…Reproduced with permission. [ 111 ] Copyright 2019, Wiley. F) Photographs of contact lens integrated with electrochromic alarm system above forefinger, and artificial eye.…”
Section: Smart Clsmentioning
confidence: 99%