Self‐adapting cyclic registration for motion‐compensated cone‐beam CT in image‐guided radiation therapy

Abstract: The cyclic motion compensation approach provides respiratory-correlated volumes with high image quality. The cyclic motion estimation is of such low sensitivity to sparse-view artifacts, that it is capable to determine high quality motion vector fields based on reconstructions of low sampled data.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
66
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 46 publications
(66 citation statements)
references
References 39 publications
0
66
0
Order By: Relevance
“…There are other approaches that have been published in the literature to improve image quality with the most common approaches using iterative reconstruction techniques after the raw data has been acquired, see (Bian et al 2010), (Bergner et al 2009), (Bergner et al 2010), (Leng et al 2008), (Li et al 2007), (Brehm et al 2012), (Brehm et al 2013), and (Mckinnon & Bates 1981) or techniques that attempt to reconstruct 4DCBCT from a one minute 3DCBCT (Yan et al 2014). RMG-4DCBCT can be used in conjunction with these approaches but it has the added benefit that it is the only technique that addresses image quality and imaging dose issues at the source of the problem; i.e., during image acquisition.…”
Section: Discussionmentioning
confidence: 99%
“…There are other approaches that have been published in the literature to improve image quality with the most common approaches using iterative reconstruction techniques after the raw data has been acquired, see (Bian et al 2010), (Bergner et al 2009), (Bergner et al 2010), (Leng et al 2008), (Li et al 2007), (Brehm et al 2012), (Brehm et al 2013), and (Mckinnon & Bates 1981) or techniques that attempt to reconstruct 4DCBCT from a one minute 3DCBCT (Yan et al 2014). RMG-4DCBCT can be used in conjunction with these approaches but it has the added benefit that it is the only technique that addresses image quality and imaging dose issues at the source of the problem; i.e., during image acquisition.…”
Section: Discussionmentioning
confidence: 99%
“…There we found that our artifact-specific cyclic registration and motion compensation (acMoCo) algorithms are extremely successful for slowly rotating CBCT systems. 6,7 In analogy to the 4D MoCo reconstruction we can formulate a 5D MoCo reconstruction:…”
Section: Methodsmentioning
confidence: 99%
“…In a first step for 5D motion estimation, our previously published 4D MoCo approach is applied to compensate for the respiratory patient motion, thus leading to high fidelity 4D CBCT images. 6,7 The main outcome of this approach are 4D MVFs denoted before as D r2 r1 , that accurately describe the lung motion between two adjacent phases as a function of the respiratory phase. In detail, and based on the wellknown FDK 20 filtered backprojection algorithm, phase-correlated, i.e.…”
Section: Methodsmentioning
confidence: 99%
“…We address this problem by using an artifact model, which predicts the shape and magnitude of the streak artifacts, combined with a deformable registration based on the Demons algorithm and a cyclic regularization [13], [14]. The first step (Fig.…”
Section: B Estimation Of Motion Vector Fieldsmentioning
confidence: 99%