2000
DOI: 10.2116/analsci.16.307
|View full text |Cite
|
Sign up to set email alerts
|

Selenite-Selective Membrane Electrodes Based on Ion Exchangers and Application to Anodic Slime

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0

Year Published

2002
2002
2013
2013

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 16 publications
1
9
0
Order By: Relevance
“…Table 8 compares the slope, response time, detection limit, and major interfering ions of the proposed selenite electrodes with those of selenite-selective electrodes reported in the literature. We can observe that, our electrodes showed larger slope, faster response time than those reported in the literature [8,10,11], while it has narrower linear range.…”
Section: Resultssupporting
confidence: 46%
See 1 more Smart Citation
“…Table 8 compares the slope, response time, detection limit, and major interfering ions of the proposed selenite electrodes with those of selenite-selective electrodes reported in the literature. We can observe that, our electrodes showed larger slope, faster response time than those reported in the literature [8,10,11], while it has narrower linear range.…”
Section: Resultssupporting
confidence: 46%
“…Piaselenol (PIS) was used in the form of 1,2-phenylenediamine selen complex as the active material for ion-selective electrode membrane sensitive to selenite ion [10]. Silicon rubber [11] was used as the active membrane matrix for selenite-selective electrode consisted of 4% dialkyldimethylammonium chloride, and QAD 86 PI. A self-made ion-selective electrode was made using Ag 2 Se as electroactive material [12], and used for the determination of selenium in biological materials.…”
Section: Introductionmentioning
confidence: 99%
“…Anodic slime contains 8 -20% of selenium, next to 20 -40% of copper. There are also Ag, Pb and Te in much smaller quantities, 0.3 -3% [23]. The newly-developed membrane sensor is applied to some samples prepared from anodic slime which are digested with acid.…”
Section: Determination Of Selenium In Anodic Slimementioning
confidence: 99%
“…The use of PVC matrix membrane sensors for SeO 3 2À determination including many sensing agents; dialkyldimethylammonium chloride [23], 1,2-phenylenediamine selen complex PIS (piaselenol) [24], and 4,6-dibromopiaselenole [25] has been received much attention. Advantages and limitations of these sensors are presented in Table 1.…”
Section: Introductionmentioning
confidence: 99%
“…The liquid membrane electrodes show long response times and low selectivity. More recently solid membrane electrodes have been prepared using various polymer matrix materials [8]. Some hydrogen ion selective membrane electrodes based on PVC-SR [9] and on a tribenzylamine neutral carrier in a PVC [10] showed pH dependence between 2.5 and 11.…”
Section: Introductionmentioning
confidence: 99%