1992
DOI: 10.1016/0584-8547(92)80017-b
|View full text |Cite
|
Sign up to set email alerts
|

Selectivity and limits of detection in inductively coupled plasma optical emission spectrometry using multivariate calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
2

Year Published

1992
1992
2015
2015

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(13 citation statements)
references
References 22 publications
0
10
0
2
Order By: Relevance
“…Three illustrative types of estimators are discussed to some detail in Section 4. Several approaches have been advanced in the literature for the first-order classical [18,28,151,152] and inverse models [19,153,154]. (The proposal of [154] is directly applicable to higher-order data.)…”
Section: Previously Proposed Methodology In Multivariate Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…Three illustrative types of estimators are discussed to some detail in Section 4. Several approaches have been advanced in the literature for the first-order classical [18,28,151,152] and inverse models [19,153,154]. (The proposal of [154] is directly applicable to higher-order data.)…”
Section: Previously Proposed Methodology In Multivariate Calibrationmentioning
confidence: 99%
“…In other words, the full S must be available. Successful application has been reported for the calibration of atomic spectra, e.g., obtained by inductively coupled plasma-optical emission spectrometry (ICP-OES) [27][28][29].…”
Section: Classical Vs Inverse Modelmentioning
confidence: 99%
“…with Gaussian distribution) and therefore the constant probability lines are circles and the radius (R) of these circles (which is here the standard deviation of the noise, often denoted by σ ε ) is independent from the sample composition and thus also from the actual absorbance values. (Note, however, that this assumption is not naturally valid for all analytical measurements [15,19].Definition of multichannel selectivity becomes, however, somewhat more complicated in other cases, and is not considered here for simplicity. )…”
Section: Error Inflationmentioning
confidence: 99%
“…The NPS for ICP-MS (1-3) and ICP-AES (4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15) have been reported and the prevailing noise types identified as: (13 white (16). Noise in the ICP from large, undesolvated wet droplets and undissociated dry particles has also been characterized extensively (17)(18)(19)(20)(21)(22).…”
Section: Introductionmentioning
confidence: 99%