2011
DOI: 10.1016/j.chroma.2011.08.052
|View full text |Cite
|
Sign up to set email alerts
|

Selective pressurized liquid extraction of three classes of halogenated contaminants in fish

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
19
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(20 citation statements)
references
References 24 publications
1
19
0
Order By: Relevance
“…In addition, the method allows low manipulation of the sample, reduced solvent consumption and lowered extraction and analysis time. Many authors [23][24][25]37,38] applied analogous extraction and purification methods on solid environmental matrices yielding comparable results, but this is the first time that this analytical procedure is carried out on biopolymer samples.…”
Section: Methods Performancementioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the method allows low manipulation of the sample, reduced solvent consumption and lowered extraction and analysis time. Many authors [23][24][25]37,38] applied analogous extraction and purification methods on solid environmental matrices yielding comparable results, but this is the first time that this analytical procedure is carried out on biopolymer samples.…”
Section: Methods Performancementioning
confidence: 99%
“…Lately, analytical procedures that combine extraction and clean-up steps have been developed. These methods involve reduced organic solvent consumption as well as reduced extraction and analysis time, and less sample handling while providing performance comparable to conventional sample preparation methods [23][24][25].…”
Section: Introductionmentioning
confidence: 99%
“…Low-(total average 160 pg L −1 ; n = 7) and mid-(total average 225 pg L −1 ; n = 3) range calibration curve reproducibility studies were performed. Statistically derived MDLs were determined by analyzing seven ∼1.5 g ww aliquots of a bowhead whale blubber sample spiked with analytes at concentrations corresponding to the penultimate calibration point (total average 7 pg L −1 ) [13]. MDLs were determined by multiplying the standard deviation by the one-sided student t-test static (99% confidence).…”
Section: Reproducibility Studies Methods Detection Limits (Mdls) Andmentioning
confidence: 99%
“…SPLE incorporating acidic silica or Florisil TM in single extraction cells may be appropriate for POPs analysis in blubber, depending on the desired blubber sample mass. Theoretically, <0.3 g of lipid (or 0.4 g of blubber assuming 75% lipid) could be extracted for PBDEs, PCBs, and OCPs using previously published Florisil TM SPLE methods in a single 100 mL extraction cell [13]. Select OCPs eliminated from this report's analyte list due to use of acidic silica may potentially be extracted if utilizing a Florisil TM SPLE method.…”
Section: Application To Environmental Samplesmentioning
confidence: 96%
See 1 more Smart Citation