2001
DOI: 10.1002/1521-4109(200111)13:16<1351::aid-elan1351>3.0.co;2-f
|View full text |Cite
|
Sign up to set email alerts
|

Selective Determination of Uric Acid by Using a β-Cyclodextrin Modified Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
18
0
1

Year Published

2003
2003
2011
2011

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 59 publications
(20 citation statements)
references
References 27 publications
(24 reference statements)
1
18
0
1
Order By: Relevance
“…Surface modifications are based on the immobilization of enzyme uricase, [6][7][8] or the modification of a UA sensing matrix layer. 9 On the other hand, activated electrodes, 10 diamonds 11 and carbon nanotube electrodes 12 have been employed as novel electrode materials.…”
Section: Introductionsupporting
confidence: 91%
“…Surface modifications are based on the immobilization of enzyme uricase, [6][7][8] or the modification of a UA sensing matrix layer. 9 On the other hand, activated electrodes, 10 diamonds 11 and carbon nanotube electrodes 12 have been employed as novel electrode materials.…”
Section: Introductionsupporting
confidence: 91%
“…The reason for this phenomenon may originate from the high concentration of UA in the interface of modified electrode due to the selective inclusion effect of β-CD. Since β-CD can readily include the neutral UA than AA monoanionic species at pH 7.0 [44]. Compared with curve B, the peak currents of AA and UA at SWCNTs/β-CD/GCE (curve C) was smaller than that of SWCNTs-β-CD/GCE, and its oxida tive potentials shifted positively.…”
Section: Electrochemical Sensor Of Aa and Ua By Swcnts-β-cd Modified Gcementioning
confidence: 99%
“…5 Its abnormal concentration level in urine and serum are symptoms of several diseases like gout, hyperuricaemia and Lesch-Nyhan syndrome. 6,7 For instance, the concentration of uric acid in the blood of patients suffering from gout increases up to 1 mmol L -1 , which is above the concentration of uric acid in blood for a healthy person. 5,8 According to literature, 8,9 the concentration of UA in serum is about 240-520 µmol L -1 and the urinary excretion is 1.49-4.46 mmol L -1 per 24 h for a healthy person.…”
Section: Introductionmentioning
confidence: 99%
“…Among them a widely used method is to coat the electrode with an ion-exchange membrane such as Nafion film, which is mainly employed to determine UA in the presence of AA at acid medium. 14,15 On the other hand, poly(3,4-dihydroxybenzaldehyde), 16 polypyrroledodecyl sulfate, 17 β-cyclodextrin, 6 carbon nanotube, 13 selfassembly monolayer of thiol 9 and clay modified electrodes 18 were used to determine UA or AA in the presence of the other without an ion-exchange membrane.…”
Section: Introductionmentioning
confidence: 99%