2011
DOI: 10.1016/j.talanta.2011.06.017
|View full text |Cite
|
Sign up to set email alerts
|

Selective determination of melamine in milk samples using 3-mercapto-1-propanesulfonate-modified gold nanoparticles as colorimetric probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
21
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(23 citation statements)
references
References 23 publications
2
21
0
Order By: Relevance
“…This was much lower than that of previously reported methods for the detection of MLM 4,10,11 and well below the safety limit. 12 The cathodic peak currents of ferricyanide for 0.5 μM MLM was reduced to 99.40% of the initial response, after 40 consecutive DPV measurements in the same condition. This indicated that the proposed method was very stable and reliable for the detection of MLM.…”
Section: Methodsmentioning
confidence: 89%
See 1 more Smart Citation
“…This was much lower than that of previously reported methods for the detection of MLM 4,10,11 and well below the safety limit. 12 The cathodic peak currents of ferricyanide for 0.5 μM MLM was reduced to 99.40% of the initial response, after 40 consecutive DPV measurements in the same condition. This indicated that the proposed method was very stable and reliable for the detection of MLM.…”
Section: Methodsmentioning
confidence: 89%
“…ecsdl.org/site/terms_use address. Redistribution subject to ECS terms of use (see 128.59.222 12. Downloaded on 2014-09-26 to IP…”
mentioning
confidence: 99%
“…As far as milk sample, it was pretreated according to previous report. 8,28 Briefly, 4 mL of milk samples were mixed with 1.2 mL of 300 g L −1 trichloroacetic acid. After being shaked for 1 min, the mixture was centrifugated at 3500 rpm for 5 min.…”
Section: Methodsmentioning
confidence: 99%
“…At present, different analytical methods, such as spectrophotometry, 7 colorimetric method, [8][9][10][11][12] luminescence quenching, 13 fluorescence, 14 chemiluminescence analysis, 15 surfaceenhanced Raman scattering, 16 gas chromatography-mass spectrometry (GC-MS), 17 high performance liquid chromatography (HPLC), 18 sweeping micellar electrokinetic chromatography (SMEC), 19 and especially, naked eye sensing with Au nanoparticles as color indicating reporter, 20 have been reported to detect MEL with good results. However, traditional spectrophotometry and colorimetric methods are easily interfered by related compounds.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, chitosan 12 , 1-(2-mercaptoethyl)-1,3,5-triazinane-2,4,6-trione 13 , 3-mercapto-1-propanesulfonate 14 , cysteamine 15 , and riboflavin 16 modified AuNPs have been fabricated as colorimetric probes for visual detection of melamine in raw milk and infant formula. Most of these methods exhibit quite high sensitivity for melamine, but the complex modification and the unstability of AuNPs limits their 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 …”
Section: Introductionmentioning
confidence: 99%