“…On the other hand, aniline ( m / z = 93) was noticeably absent in the diesel generator exhaust. An upper value of the aniline concentration is determined to be 0.3 ppb, based on the similar ionization probability of aniline in comparison to benzene, being only a factor 1.67 lower . Note that this is not the REMPI-TOFMS instrument detection limit for aniline but rather the minimum concentration that would have been detectable in the diesel generator exhaust without significant ion signal overload on the detector at other masses.…”
Section: Resultsmentioning
confidence: 94%
See 2 more Smart Citations
“…On the other hand, aniline ( m / z = 93) was noticeably absent in the diesel generator exhaust. An upper value of the aniline concentration is determined to be 0.3 ppb, based on the similar ionization probability of aniline in comparison to benzene, being only a factor 1.67 lower . Note that this is not the REMPI-TOFMS instrument detection limit for aniline but rather the minimum concentration that would have been detectable in the diesel generator exhaust without significant ion signal overload on the detector at other masses.…”
Section: Resultsmentioning
confidence: 94%
“…The concentration of a target analyte is derived from the ratio between its ion signal intensity and that of the same analyte as present in the calibration gas mix, normalized for possible laser energy changes. Concentrations of those diesel generator exhaust analytes not present in the calibration mix were derived from the ionization probability ratios between benzene and such analytes as found by Cool and co-workers . In the case of concentration calibration of compounds that are in their crystalline form at room temperature, such as PAHs, a diffusion tube-based delivery system , was designed and applied to generate a known concentration of a specific analyte in the gas phase.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For this purpose various strategies have been suggested including REMPI for selective ionization [16,18,19]. However, Haefliger and Zenobi demonstrated that single wavelength, two photon REMPI is not very selective for desorbed PAH because of the high temperature of the PAH gas [17].…”
Section: Evolution Of the Mass Spectra With The Ionization Fluence: Smentioning
confidence: 98%
“…REMPI measurements of PAHs in a different environment were also performed by Cool and co-workers. 25 While most flames studied previously have burnt hydrocarbon fuels, we have recently started to investigate the fuel-rich flame chemistry of ethanol, ethanol being a simple prototype of an oxygenated fuel. Motivation for this study was the potential use of ethanol as an alternative non-fossil fuel 26 or as a fuel additive.…”
Section: Introductionmentioning