2021
DOI: 10.1016/j.aca.2021.338387
|View full text |Cite
|
Sign up to set email alerts
|

Selective colorimetric urine glucose detection by paper sensor functionalized with polyaniline nanoparticles and cell membrane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
28
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 33 publications
(29 citation statements)
references
References 55 publications
1
28
0
Order By: Relevance
“…Next, we plotted the absorbance ratio (λ 600 /λ 430 ) of PAni-NPs vs. the pH of the solution ranging from 3 to 9 ( Figure 2 b). An excellent linearity is observed, particularly at pH 5–8 (as shown in the inset of Figure 2 b), which is consistent with the results of our previous study [ 22 ]. It should be noted that the linear range of PAni-NPs for the colorimetric response is sufficient for various biomedical applications.…”
Section: Resultssupporting
confidence: 92%
See 2 more Smart Citations
“…Next, we plotted the absorbance ratio (λ 600 /λ 430 ) of PAni-NPs vs. the pH of the solution ranging from 3 to 9 ( Figure 2 b). An excellent linearity is observed, particularly at pH 5–8 (as shown in the inset of Figure 2 b), which is consistent with the results of our previous study [ 22 ]. It should be noted that the linear range of PAni-NPs for the colorimetric response is sufficient for various biomedical applications.…”
Section: Resultssupporting
confidence: 92%
“…PAni-NPs were synthesized using previously reported methods, with a few modifications [ 22 ]. A 25 mL APS solution at a 91.2 mg/mL concentration was added dropwise to a 60 mL solution containing 1.80 g pectin, 9 mL HCl (11 N), and 0.90 g aniline.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In a previous study, we analyzed the thickness of the RBCM per unit area according to the amount of RBCM. [ 39 ] In the case of the vesicle fusion method, the RBCM membrane was designed to have a thickness of approximately 400 nm to achieve sufficient mechanical strength, which is equivalent to 80 cell membranes. Therefore, the total thickness of the GO–GRGDS–AQP (vesicle fusion coating) membrane was estimated to be ≈700 nm, while that of the GO–GRGDS–AQP (interlayer) was 611 nm, as shown in Figure S4b , Supporting Information.…”
Section: Resultsmentioning
confidence: 99%
“…Many lab-on-paper platforms with integrated colorimetric detection [97][98][99][100][101] have been proposed for determining the glucose concentration in human urine samples. de Oliveira et al [102] developed 2D and 3D lab-on-paper platforms for the integrated colorimetric detection of glucose, total protein and nitrite in serum and artificial urine.…”
Section: Glucose Analysismentioning
confidence: 99%