2012
DOI: 10.1039/c2jm15664d
|View full text |Cite
|
Sign up to set email alerts
|

Selective and sensitive ratiometric detection of Hg2+ in 100% aqueous solution with triazole-based dansyl probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
39
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 116 publications
(40 citation statements)
references
References 66 publications
1
39
0
Order By: Relevance
“…Therefore, the electron transfer from Au 25 NCs to Hg 2+ ions can occur spontaneously when the Hg 2+ is binding to the NCs. Sensing the Hg 2+ ions had also accomplished by fluorescent molecules, QDs and carbon dots (C‐Dot) due to facilitating non‐radiative electron/hole recombination through an effective electron transfer process . It should be noted that the relative amplitude of the DF decreases with increasing Hg 2+ concentrations, although the decay rate is found to remain constant.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, the electron transfer from Au 25 NCs to Hg 2+ ions can occur spontaneously when the Hg 2+ is binding to the NCs. Sensing the Hg 2+ ions had also accomplished by fluorescent molecules, QDs and carbon dots (C‐Dot) due to facilitating non‐radiative electron/hole recombination through an effective electron transfer process . It should be noted that the relative amplitude of the DF decreases with increasing Hg 2+ concentrations, although the decay rate is found to remain constant.…”
Section: Resultsmentioning
confidence: 99%
“…8), and a linear regression equation of DF¼FeF 0 ¼ 3911.8Ce 697.8 (where C is the concentration of Hg 2þ ions, F and F 0 represents the fluorescence intensity with and without Hg 2þ ions). The detection limit can be calculated by the formula [15,45,46]:…”
Section: Detection Of Hg 2þ Ionsmentioning
confidence: 99%
“…25,26 In fact, various methods for the sensitive and selective detection of the heavy metal ions have been reported. [28][29][30][31][32] For example, the performance of a conventional and unqualified rhodamine-based fluorescent Hg 2+ sensor was greatly improved by Tian and co-workers via the introduction of triazole structures. [28][29][30][31][32] For example, the performance of a conventional and unqualified rhodamine-based fluorescent Hg 2+ sensor was greatly improved by Tian and co-workers via the introduction of triazole structures.…”
Section: Introductionmentioning
confidence: 99%