1998
DOI: 10.1016/s0039-9140(98)00118-0
|View full text |Cite
|
Sign up to set email alerts
|

Selective and sensitive fluorometric determinations of cobalt(II) and hydrogen peroxide with fluorescein-hydrazide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
23
0

Year Published

2001
2001
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 66 publications
(23 citation statements)
references
References 12 publications
0
23
0
Order By: Relevance
“…Therefore, rapid, accurate and reliable detection of H 2 O 2 is of great significance to not only scientific research but also practical applications. Compared with many traditional detection approaches [5][6][7][8], the newly emerging electrochemical methods have attracted much attention because of its high sensitivity, fast detection, low cost, and ease of operation [9]. So far, electrochemical sensors based on enzymes have been fully developed due to their high sensitivity and extremely good selectivity.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, rapid, accurate and reliable detection of H 2 O 2 is of great significance to not only scientific research but also practical applications. Compared with many traditional detection approaches [5][6][7][8], the newly emerging electrochemical methods have attracted much attention because of its high sensitivity, fast detection, low cost, and ease of operation [9]. So far, electrochemical sensors based on enzymes have been fully developed due to their high sensitivity and extremely good selectivity.…”
Section: Introductionmentioning
confidence: 99%
“…Hence, we developed a handy and highly sensitivity method for the determination of ROS, including H 2 O 2 . We have already developed methods for the fluorometric determination of cobalt(II) and H 2 O 2 with fluorescein hydrazide (FH), 21) however, the method adopted for the determination of H 2 O 2 exhibited remarkably poor reproducibility. In this study, method to obtain a more reproducible and sensitive spectrofluorimetric determination of H 2 O 2 and other ROS were examined.…”
mentioning
confidence: 99%
“…1,2 Many analytical methods have been reported for such measurements, including electroanalytical techniques, [3][4][5] spectrophotometry, 6,7 chemiluminescence, 8,9 and fluorometry. [10][11][12] Among these methods, most are based on the enzyme (peroxidase and catalase) catalytic reaction. Enzymatic determinations of H2O2 have drawn increasing interest due to their unusual sensitivity, selectivity and simplicity.…”
Section: Introductionmentioning
confidence: 99%