1999
DOI: 10.1109/59.761882
|View full text |Cite
|
Sign up to set email alerts
|

Selection of robust installing locations and feedback signals of FACTS-based stabilizers in multi-machine power systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
31
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 85 publications
(31 citation statements)
references
References 10 publications
0
31
0
Order By: Relevance
“…While the effectiveness of a DTA index has already been verified [8][9][10][11][12][13][14][15][16][17][18], in this section, eigenvalue calculations are used to demonstrate the effectiveness of the proposed stabiliser-tuning strategy.…”
Section: Case Studymentioning
confidence: 99%
See 2 more Smart Citations
“…While the effectiveness of a DTA index has already been verified [8][9][10][11][12][13][14][15][16][17][18], in this section, eigenvalue calculations are used to demonstrate the effectiveness of the proposed stabiliser-tuning strategy.…”
Section: Case Studymentioning
confidence: 99%
“…In [8][9][10], DTA has been extended for application in a multi-machine power system and demonstrated to be basically equivalent to modal analysis. The DTA index denotes the impact from a reconstructed feedback signal of a stabiliser to the selected oscillation loop and is a summary in two loops.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…These problems are study in literature, a modal analysis algorithm has been suggested for placement of SVCs and selection of stability signals in power systems environments [14]. A new eigen solution free method of modal control analysis for the selection of the robust installing locations and feedback signals of FACTS based stabilizers in large-scale power systems is presented in [15]. Many literatures studies have made it clear that variable impedance apparatus such as a static Var compensator (SVC) and a variable series capacitor (VSrC) can improve the steady-state stability (or the small signal stability).…”
Section: Sensitivity Based Methodsmentioning
confidence: 99%
“…References [3]- [5], classify three broad categories such as a sensitivity based methods, optimization based method, and artificial intelligence based techniques for placement of FACTS controllers from different operating conditions viewpoint in multi-machine power systems. The various sensitivity based methods have been proposed in literatures includes eigen-value analysis based methods [6]- [12], modal analysis techniques [13]- [15], index methods [16]- [23], residue-based methods [24]- [25], [43], [168], [169], and other sensitivity based methods [26]- [37], [53], [157]- [167], [201].…”
Section: Introductionmentioning
confidence: 99%