2019
DOI: 10.1016/j.energy.2018.11.024
|View full text |Cite
|
Sign up to set email alerts
|

Selection of refrigerants for a modified organic Rankine cycle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
14
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 47 publications
(17 citation statements)
references
References 28 publications
1
14
0
2
Order By: Relevance
“…Overall efficiency depends on the efficiency and effectiveness of individual system components (Kajurek et al, 2019):  pump efficiency;  isentropic turbine efficiency;  mechanical turbine efficiency;  generator efficiency;  condenser thermal efficiency;  evaporator thermal efficiency;  regenerator thermal efficiency. Efficiency also depends on the amount of additional energy needed to pump the cooling and heating medium through the exchangers (these are pumps or fans).…”
Section: The Orc Device Efficiencymentioning
confidence: 99%
See 1 more Smart Citation
“…Overall efficiency depends on the efficiency and effectiveness of individual system components (Kajurek et al, 2019):  pump efficiency;  isentropic turbine efficiency;  mechanical turbine efficiency;  generator efficiency;  condenser thermal efficiency;  evaporator thermal efficiency;  regenerator thermal efficiency. Efficiency also depends on the amount of additional energy needed to pump the cooling and heating medium through the exchangers (these are pumps or fans).…”
Section: The Orc Device Efficiencymentioning
confidence: 99%
“…In previous studies (Kajurek et al, 2017(Kajurek et al, , 2019 it was determined which working fluid is best to be used in ORC systems. From the point of energy efficiency view, ammonia proved to be unrivaled, however, due to the fact that the temperature of the critical point for ammonia is 132.4 °C, it cannot be used in systems where a higher evaporator temperature in the ORC system is expected.…”
Section: Introductionmentioning
confidence: 99%
“…In Poland, thermo-modernization programs are very well developed, aimed at reducing energy consumption, and thus reducing air pollution. Unfortunately, not everything has been achieved yet (Owczarek & Baryłka, 2019;Rusowicz & Ruciński, 2011;Kajurek et al, 2019). While the quality of outdoor air in the current legal system in Poland is difficult to improve, it becomes very important to maintain good indoor air quality.…”
Section: Introductionmentioning
confidence: 99%
“…One efficient way to recover energy from waste heat sources is the organic Rankine cycle (ORC). When recovering energy from low-grade heat sources, an ORC system is more efficient than a conventional Rankine cycle [9,10]; this is because the ORC system uses an organic working fluid (WF) with a low boiling point [11]. When recovering energy from a cold source, the ORC system is also an efficient option because the organic WF has a low freezing point and a low boiling point.…”
Section: Introductionmentioning
confidence: 99%