2019
DOI: 10.1016/j.jtcvs.2018.06.102
|View full text |Cite
|
Sign up to set email alerts
|

Selection of prosthetic aortic valve and root replacement in patients younger than age 30 years

Abstract: Objective: Long-term outcomes of prosthetic aortic valve/root replacement in patients aged 30 years or younger are not well understood. We report our single institutional experience in this young cohort.Methods: From 1998 to 2016, 99 patients (age range, 16-30 years) underwent aortic valve replacement (n ¼ 57), aortic valve replacement and supracoronary ascending aorta replacement (n ¼ 6), or aortic root replacement (n ¼ 36). A prospectively maintained aortic valve database was retrospectively reviewed to comp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 31 publications
0
4
0
1
Order By: Relevance
“…Mazine and colleagues 11 reported mean aortic pressure gradients in adults after mechanical heart valve replacement between 9.3 and 17 mm Hg in a systemic review and meta-analysis. Interestingly, Milewski and colleagues 12 found an increase in the mean aortic transvalvular gradient over time even in mechanical valves, reaching 20 mm Hg at 9.5 years postoperatively. The mean transvalvular pressure gradient over time was low (<6 mm Hg) in this study, comparable to the in vitro data for this valve.…”
Section: Discussionmentioning
confidence: 99%
“…Mazine and colleagues 11 reported mean aortic pressure gradients in adults after mechanical heart valve replacement between 9.3 and 17 mm Hg in a systemic review and meta-analysis. Interestingly, Milewski and colleagues 12 found an increase in the mean aortic transvalvular gradient over time even in mechanical valves, reaching 20 mm Hg at 9.5 years postoperatively. The mean transvalvular pressure gradient over time was low (<6 mm Hg) in this study, comparable to the in vitro data for this valve.…”
Section: Discussionmentioning
confidence: 99%
“…Milewski et al [21] presented an 18-year experience with AV replacement. The study compared the immediate and long-term results of AV replacement with biological and mechanical prostheses in young people.…”
Section: Discussionmentioning
confidence: 99%
“…Em pacientes mais jovens, os estudos são bastante limitados a longo prazo, não sendo possível definir a diferença entre necessidade de reoperação ou taxas de mortalidade nos dois tipos de prótese. Dessa forma, o uso da prótese mecânica, apesar de ser o mais recomendado, deve ser avaliado de acordo com os desejos e necessidades de cada paciente (MILEWSKI et al, 2019).…”
Section: Revisão Bibliográficaunclassified