1999
DOI: 10.1007/s002160051275
|View full text |Cite
|
Sign up to set email alerts
|

Selection of optimum pH for the iodate determination using differential pulse polarography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0
1

Year Published

2004
2004
2011
2011

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 0 publications
0
1
0
1
Order By: Relevance
“…Several analytical techniques have been reported for the determination of iodate, including spectrophotometry (Afkhami & Mosaed, 2002;Pena-Pereira, Senra-Ferreiro, Lavilla, & Bendicho, 2010;Silva, De Oliveira, & Neves, 1998), chemiluminescence (Zui & Terletskaya, 1995), ion chromatography (McTaggart, Butler, Haddad, & Middleton, 1994;Rebary, Paul, & Ghosh, 2010), gas chromatography-mass spectrometry (Reddy-Noone, Jain, & Verma, 2007;Shin, Oh-Shin, Kim, & Ryu, 1996), high performance liquid chromatography (Xu, Li, Gu, & Paeng, 2004), indirect atomic absorption spectrophotometry (Chakraborty & Das, 1989), transient isotachophoresis-capillary zone electrophoresis (Wang, Zhao, Shen, Tang, & Wang, 2009), and electroanalysis (Huang, Li, Chen, & Wang, 2008;Lin, 1999;Sharma & Songara, 2007). Most of these methods are either time consuming, or require complicated and expensive instruments, or are not very sensitive.…”
Section: Introductionmentioning
confidence: 99%
“…Several analytical techniques have been reported for the determination of iodate, including spectrophotometry (Afkhami & Mosaed, 2002;Pena-Pereira, Senra-Ferreiro, Lavilla, & Bendicho, 2010;Silva, De Oliveira, & Neves, 1998), chemiluminescence (Zui & Terletskaya, 1995), ion chromatography (McTaggart, Butler, Haddad, & Middleton, 1994;Rebary, Paul, & Ghosh, 2010), gas chromatography-mass spectrometry (Reddy-Noone, Jain, & Verma, 2007;Shin, Oh-Shin, Kim, & Ryu, 1996), high performance liquid chromatography (Xu, Li, Gu, & Paeng, 2004), indirect atomic absorption spectrophotometry (Chakraborty & Das, 1989), transient isotachophoresis-capillary zone electrophoresis (Wang, Zhao, Shen, Tang, & Wang, 2009), and electroanalysis (Huang, Li, Chen, & Wang, 2008;Lin, 1999;Sharma & Songara, 2007). Most of these methods are either time consuming, or require complicated and expensive instruments, or are not very sensitive.…”
Section: Introductionmentioning
confidence: 99%
“…Distintos protocolos têm sido elaborados para a análise de iodato, tais como, espectrofotometria [1,[10][11][12][13][14][15][16][17][18][19][20][21]; métodos em FIA [22][23][24][25][26][27]; cromatografia iônica [28,29]; cromatografia gasosa [2,30]; cromatografia liquida [31]; eletroquímica [23,24,[32][33][34][35][36][37] e quimiluminescência [38].…”
unclassified