IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233) 1999
DOI: 10.1109/pesw.1999.747535
|View full text |Cite
|
Sign up to set email alerts
|

Selection of locations and input signals for multiple SVC damping controllers in large scale power systems

Abstract: This paper presents a methodology to simultaneously determine the locations and input signals for multiple Static Var Compensators (SVCs) in order to damp multiple electromechanical oscillation modes in extensive power systems. This methodology combines Modal control theory and Multiple Input Multiple Output (MIMO) control theory. Modal control theory indicates the sensitivity of a controller to the critical mode of interest, whilst MIMO control theory gives a measure of interactions caused by decentralized co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
4
0

Year Published

2005
2005
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 15 publications
(1 reference statement)
1
4
0
Order By: Relevance
“…It is clear that (18) becomes (9). Similarly, pre-and postmultiply its left and right sides of (17) by diag{P −1 , P −1 , P −1 }, respectively, and (17) becomes (10). This completes the proof of Theorem 1.…”
Section: Fwm Approach-based Facts-ward Controller Designsupporting
confidence: 54%
See 1 more Smart Citation
“…It is clear that (18) becomes (9). Similarly, pre-and postmultiply its left and right sides of (17) by diag{P −1 , P −1 , P −1 }, respectively, and (17) becomes (10). This completes the proof of Theorem 1.…”
Section: Fwm Approach-based Facts-ward Controller Designsupporting
confidence: 54%
“…In Ref. [10], the residue analysis method is applied to choose the locations and input signals for multiple static var compensator (SVC) damping controllers in large scale-power systems, but it is only valid for a single type of input signals, which suffers from a scaling problem when compared to the strength of signals of a widely differing physical significance, such as power flow in a tieline, bus frequency, shaft speed, and angle shift, and so on [1]. In Ref.…”
Section: Introductionmentioning
confidence: 99%
“…The essential step in all design methods of a WAPSS is to determine the optimal bus on which the feedback frequency should be measured and the generator at another area where the WAPSS should be placed. A large number of studies in the literature deal with the placement of the meters and WAPSSs to achieve the highest system observability and controllability based on a sensitivity analysis [11], a geometric-based approach [12], and wide-area damping controllers [9]. There are also several WAPSS design schemes proposed in the literature; see for example [7,8] and [13].…”
Section: Introductionmentioning
confidence: 99%
“…The fundamental role of LPSS is to increase damping to the oscillation of rotor of the generator by controlling its excitation using Automatic Voltage Regulator (AVR) with auxiliary stabilizing signal [2]. The CPSS use local signal as an input but this type of controller not always able to damp out the inter-area oscillations because local signal based controller do not have global observation [3].…”
Section: Iintroductionmentioning
confidence: 99%