Encyclopedia of Earthquake Engineering 2014
DOI: 10.1007/978-3-642-36197-5_175-1
|View full text |Cite
|
Sign up to set email alerts
|

Seismometer Self-Noise and Measuring Methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(17 citation statements)
references
References 20 publications
0
17
0
Order By: Relevance
“…Also shown in green is the SP L4 requirement ment methods, which can be only as good as the reference sensors used-see e.g. Ringler et al (2014). At the limit of performance that we reach (below 10 −9 m/s 2 / √ Hz), it is often difficult to discriminate between self-noise, environmental perturbations and mathematical artefacts to data processing (sampling, synchronization.…”
Section: Limitations Of the Vbb Noise Modelmentioning
confidence: 93%
See 1 more Smart Citation
“…Also shown in green is the SP L4 requirement ment methods, which can be only as good as the reference sensors used-see e.g. Ringler et al (2014). At the limit of performance that we reach (below 10 −9 m/s 2 / √ Hz), it is often difficult to discriminate between self-noise, environmental perturbations and mathematical artefacts to data processing (sampling, synchronization.…”
Section: Limitations Of the Vbb Noise Modelmentioning
confidence: 93%
“…Due to sensitivity to the electronics components' properties and performance, each long-period seismometer has its own characteristics and often quality variations can change the performance between different instruments of the same model sensor as described in Ringler et al (2014). The sensor self-noise is therefore often given by providers as a general shape with intrinsic variability, e.g.…”
Section: The Need Of a Noise Model For Insightmentioning
confidence: 99%
“…To determine a quantitative self-noise model, the measurement of seven quiet days, recorded after two days of settling, was compared with the noise record of a collocated STS-2 seismometer (International Federation of Digital Seismograph Networks [FDSN] ID: OE.CONA.51.BHZ). Details of determining an instrument self-noise using one or two reference sensors can be found in Ringler et al (2014), but given that the self-noise of the CMG-40T-OBS is orders of magnitude higher than the one of an STS-2, we used the simple method of Holcomb (1989) to calculate a self-noise curve (see Fig. 2 and Table 1).…”
Section: Sensor Self-noisementioning
confidence: 99%
“…Different coherence analytical techniques, including the two-and three-sensor methods, have been investigated well. The three-sensor method has become the preferred approach for estimating self-noise of broadband sensors owing to its relative stability and robustness in a broad range of frequencies (Ringler et al 2015b). During the mathematical computation, the Welch method is typically adopted to evaluate the signal power spectral density (PSD), wherein specific parameters, such as sample size, sample rate, bandwidth, and windowing, need to be decided before the computation.…”
Section: Introductionmentioning
confidence: 99%
“…Several studies (Holcomb 1990;Sleeman and Melichar 2012;Tasič and Runovc 2013;Gerner and Bokelmann 2013;Ringler et al 2015aRingler et al , 2015bGerner et al 2017) have shown that sensor misalignment is an important source of error during self-noise testing of seismometers based on collocation methods. A synthetic test was conducted to quantify the effect of sensor misalignment as a function of signal-to-noise ratio (SNR) on the self-noise estimate.…”
Section: Introductionmentioning
confidence: 99%