2023
DOI: 10.3390/ma16072718
|View full text |Cite
|
Sign up to set email alerts
|

Seismic Tests of Full Scale Reinforced Concrete T Joints with Light External Continuous Composite Rope Strengthening—Joint Deterioration and Failure Assessment

Abstract: Beam–column connections (joints) are one of the most critical elements which govern the overall seismic behavior of reinforced concrete (RC) structures. Especially in buildings designed according to previous generation codes, joints are often encountered with insufficient transverse reinforcement detailing, or even with no stirrups, leading to brittle failure. Therefore, externally bonded composite materials may be applied, due to the ease of application, low specific weight and corrosion-free properties. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 38 publications
0
5
0
Order By: Relevance
“…Figure 14 shows the effect of different damage-control fuses on the ductility of the beam [30]. The structural design of the fuses greatly impacts the joints.…”
Section: Ductility Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 14 shows the effect of different damage-control fuses on the ductility of the beam [30]. The structural design of the fuses greatly impacts the joints.…”
Section: Ductility Analysismentioning
confidence: 99%
“…The yield load and peak load of each specimen were calculated using the Park method [29], and the results are shown in Figure 13 (Point A Figure 14 shows the effect of different damage-control fuses on the ductility of the beam [30]. The structural design of the fuses greatly impacts the joints.…”
Section: Ductility Analysismentioning
confidence: 99%
“…In this study, a representative example of the above category is investigated. The examined structure is an eight-story RC frame (Figure 2a) designed by Hatzigeorgiou and Liolios [91], only for gravity loads, without seismic provisions [92] or retrofitting [93][94][95][96][97][98]. Additionally, according to the design methodology adopted in Greece before 1984, this building lacks capacity design and shear walls.…”
Section: Description and Modelling Of The Examined Buildingmentioning
confidence: 99%
“…In this study, a representative example of the above category is investigated. The examined structure is an eight-story RC frame (Figure 2a) designed by Hatzigeorgiou and Liolios [91], only for gravity loads, without seismic provisions [92] or retrofitting [93][94][95][96][97][98]. Additionally, according to the design methodology adopted in Greece before 1984, this building lacks capacity design and shear walls.…”
Section: Description and Modelling Of The Examined Buildingmentioning
confidence: 99%