2007
DOI: 10.1061/(asce)0733-9445(2007)133:11(1560)
|View full text |Cite
|
Sign up to set email alerts
|

Seismic Performance of Self-Centering Structural Walls Incorporating Energy Dissipators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
115
0
2

Year Published

2012
2012
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 265 publications
(126 citation statements)
references
References 10 publications
0
115
0
2
Order By: Relevance
“…In order to improve the lateral capability of a rocking unreinforced wall under inplane seismic loading, unbonded prestressed technology has been incorporated in masonry walls to provide self-centering behavior [8,9]. Unbonded prestressed tendons were applied in the center of a concrete wall or a masonry wall in some tests, such as tests conducted by Restrepo et al [10][11][12]. Several schematic diagrams and some simple information of these tests are shown in Figures 2(a)-2(c).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to improve the lateral capability of a rocking unreinforced wall under inplane seismic loading, unbonded prestressed technology has been incorporated in masonry walls to provide self-centering behavior [8,9]. Unbonded prestressed tendons were applied in the center of a concrete wall or a masonry wall in some tests, such as tests conducted by Restrepo et al [10][11][12]. Several schematic diagrams and some simple information of these tests are shown in Figures 2(a)-2(c).…”
Section: Introductionmentioning
confidence: 99%
“…If rocking walls contain special energy dissipators, such as those shown in Figures 2(e) and 2(f), then a full hysteresis loop would be obtained [10].…”
Section: Introductionmentioning
confidence: 99%
“…Experimental research was conducted on single rocking and hybrid wall panels under both quasi-static [6][7][8] and dynamic loading [9] proving the good performance of these systems if detailed appropriately. The dynamic interaction between rocking and hybrid walls and the rest of the structure was investigated during the DSDM project [10] in which shake table tests were conducted on a three story half-scale precast concrete structure whose lateral force resisting system consisted entirely on rocking and hybrid walls [11,12].…”
Section: Introductionmentioning
confidence: 99%
“…Muro autocentrado y comportamiento histerético idealizado del sistema híbrido. (Restrepo y Rahman, 2007;Pampanin, 2005) Desde la década anterior se ha estudiado el comportamiento de muros de concreto prefabricado con tendones de postensado no adherido (Kurama et al, 1999;Holden et al, 2003;Restrepo y Rahman, 2007). Holden et al (2003) ensayaron muros a escala 1:2 con cargas laterales cíclicas reversibles y compararon su comportamiento con el de muros de concreto reforzado.…”
unclassified
“…Estas investigaciones mostraron las características de autocentrado y disminución de los desplazamientos residuales del sistema con postensado no adherido. Restrepo y Rahman (2007) ensayaron muros a escala 1:2 con cargas laterales cíclicas reversibles y compararon el comportamiento registrado en especímenes con postensado no adherido y diferentes proporciones de barras disipadoras de acero dúctil para proveer de disipación de energía; asimismo, propusieron recomendaciones para el diseño de muros no acoplados.…”
unclassified