2008
DOI: 10.1016/j.engstruct.2008.04.013
|View full text |Cite
|
Sign up to set email alerts
|

Seismic design and behavior of post-tensioned steel connections including effects of a composite slab

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
44
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 44 publications
(50 citation statements)
references
References 6 publications
3
44
0
Order By: Relevance
“…This failure mode, which resulted in loss of the initial beam strand force by 13%, was never observed in prior beamto-column connection tests [10,13]. Vertical stiffeners were welded to the beam flange inner side and web to reinforce the beam compression toe, so the frame could be retested.…”
Section: Test Resultsmentioning
confidence: 88%
See 2 more Smart Citations
“…This failure mode, which resulted in loss of the initial beam strand force by 13%, was never observed in prior beamto-column connection tests [10,13]. Vertical stiffeners were welded to the beam flange inner side and web to reinforce the beam compression toe, so the frame could be retested.…”
Section: Test Resultsmentioning
confidence: 88%
“…On the other hand, the post-yielding stiffness ratio and the energy dissipation factor for PT connections (Table I(c)) were within the ranges (0.1 0.150, 7 1.0) suggested by Kim [7]. Following the connection design procedure proposed by Chou et al [10], the connection moment at a drift of 4%, M 4% , reached about 0.9 M np at the column face, M R ≈ 0.3M np of which was provided by the RFPs and M ST ≈ 0.6M np of which was provided by the strands (Table I(b)):…”
Section: Introductionmentioning
confidence: 87%
See 1 more Smart Citation
“…For the beam under either positive bending or negative bending, the openings in the composite specimen are similar to those in the bare steel specimen. Therefore, the proposed slab details improve the self-centering behavior of a PT connection with a continuous composite slab, which provides some restraint due to longitudinal reinforcement and wire mesh across the beam-column interface [13].…”
Section: Effects Of a Composite Slabmentioning
confidence: 99%
“…This restraint increased negative bending moments on the order of 40-50% compared with the bare steel subassembly, resulting in loss of self-centering capabilities. A later study [13] showed that the self-centering behavior is maintained if deck flutes are discontinuous at the column centerline and the connection moment contributed by longitudinal reinforcement is considered in design. Since the steel wire mesh, longitudinal reinforcement, and concrete were placed across the column centerline, the slab opened at a medium-to-high story drift after the wire mesh fractured.…”
Section: Introductionmentioning
confidence: 98%