2017
DOI: 10.1007/s10518-017-0220-9
|View full text |Cite
|
Sign up to set email alerts
|

Seismic behaviour of timber-laced stone masonry buildings before and after interventions: shaking table tests on a two-storey masonry model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 24 publications
(6 citation statements)
references
References 14 publications
0
6
0
Order By: Relevance
“…A number of shaking table tests have been performed on reduced-scale masonry structures with flexible diaphragms according to similitude laws. Tests were performed successfully on single-storey masonry buildings (Okail et al 2011, Rafi et al 2018Kallioras et al 2018, Paquette and Bruneau 2003, Paquette et al 2004) and multistorey masonry buildings (Mendes et al 2014, Deng et al 2019, Mouzakis et al 2018, Senaldi et al 2020, 2005. The size effect of units can be unignorable when the scale of masonry structures are significantly reduced Beyer 2014a-b, Mohammed andHughes 2011).…”
Section: Shaking Table Tests Have Been Considered As An Appropriate A...mentioning
confidence: 99%
“…A number of shaking table tests have been performed on reduced-scale masonry structures with flexible diaphragms according to similitude laws. Tests were performed successfully on single-storey masonry buildings (Okail et al 2011, Rafi et al 2018Kallioras et al 2018, Paquette and Bruneau 2003, Paquette et al 2004) and multistorey masonry buildings (Mendes et al 2014, Deng et al 2019, Mouzakis et al 2018, Senaldi et al 2020, 2005. The size effect of units can be unignorable when the scale of masonry structures are significantly reduced Beyer 2014a-b, Mohammed andHughes 2011).…”
Section: Shaking Table Tests Have Been Considered As An Appropriate A...mentioning
confidence: 99%
“…Different studies on these problems can be found in the literature. A single halfscale stone masonry structure was constructed on a rigid steel base connected to a shake table [21]. Three dry stone masonry models scaled by a factor of 0.55 were constructed outside the shake table on a concrete base frame simultaneously [22], but the process of moving those structures up to the shake table was not reported.…”
Section: Introductionmentioning
confidence: 99%
“…Different campaigns with this problem can be found in the literature. Single half-scale stone masonry was constructed on a rigid steel base connected to the shake table [9]. Three dry stone masonry models scaled by a factor of 0.55 were constructed outside the shake table on a concrete base frame simultaneously [10], but the process of moving those structures on the shake table is missing.…”
Section: Introductionmentioning
confidence: 99%