2016
DOI: 10.1063/1.4937534
|View full text |Cite
|
Sign up to set email alerts
|

Segmentation of nanotomographic cortical bone images for quantitative characterization of the osteoctyte lacuno-canalicular network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(12 citation statements)
references
References 21 publications
0
12
0
Order By: Relevance
“…The total X-ray dose imparted to the specimens can be estimated from the incident flux density ( Howells et al, 2009 ), which was different when using the pinhole (experiment 1) and the Fresnel zone plate (FZP) (experiments 2 and 3) to define the beam on the sample. Assuming a bone composition of pure hydroxyapatite [Ca 10 (PO 4 ) 6 (OH) 2 ] with density 2 g/cm 3 , and X-ray flux densities of 2.3 × 10 5 photons/μm 2 for the pinhole and 1.3 × 10 7 photons/μm 2 when using the FZP, we estimate that doses of the order of 10 6 Gy and 5.6 × 10 7 Gy, respectively, were imparted to the bone specimens during PXCT scanning ( Ciani et al, 2016 ). At these X-ray doses, it would only be feasible to image organic tissue intact with cryogenic protection against radiation damage ( Howells et al, 2009 ).…”
Section: Methodsmentioning
confidence: 98%
See 1 more Smart Citation
“…The total X-ray dose imparted to the specimens can be estimated from the incident flux density ( Howells et al, 2009 ), which was different when using the pinhole (experiment 1) and the Fresnel zone plate (FZP) (experiments 2 and 3) to define the beam on the sample. Assuming a bone composition of pure hydroxyapatite [Ca 10 (PO 4 ) 6 (OH) 2 ] with density 2 g/cm 3 , and X-ray flux densities of 2.3 × 10 5 photons/μm 2 for the pinhole and 1.3 × 10 7 photons/μm 2 when using the FZP, we estimate that doses of the order of 10 6 Gy and 5.6 × 10 7 Gy, respectively, were imparted to the bone specimens during PXCT scanning ( Ciani et al, 2016 ). At these X-ray doses, it would only be feasible to image organic tissue intact with cryogenic protection against radiation damage ( Howells et al, 2009 ).…”
Section: Methodsmentioning
confidence: 98%
“…Cortical bone samples from the tibial diaphysis of rat bones were analyzed through a quantitative method we have developed, previously reported by Ciani et al (2016) which provides a microarchitectural characterization of the LCN in terms of a morphological description of the osteocyte lacunae and a geometrical description of the canaliculi. Fig.…”
Section: Introductionmentioning
confidence: 99%
“…Very few publications have recently characterised osteocyte lacunae and LCN ptychographic parameters in rats. [91][92][93] Main parameters used are presented in Table 1.…”
Section: Ptychographic X-ray Ctmentioning
confidence: 99%
“…Ciani et al 92,93 applied SR ptychographic X-ray CT to characterise the lacunae and LCN in a male Wistar rat model of glucocorticoid-induced osteoporosis (GIO). After acclimation, at 19 weeks of age, the rats were randomly assigned to a control group (SHAM) or a methylprednisolone-treated group (GIO).…”
Section: Ptychographic X-ray Ctmentioning
confidence: 99%
See 1 more Smart Citation