Secondary Procedures After Infrarenal Abdominal Aortic Aneurysms Endovascular Repair With Second-Generation Endografts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 25 publications
0
16
0
Order By: Relevance
“…Device-induced aneurysm sac significant changes might alter the device integrity. 20,21 Improved device designs more prone to inducing significant AAA exclusion might also be more likely to be crushed by the aneurysmal sac collapse together with loss of patency. In our study, iliac branch occlusions were more likely found in aneurysms with any shrinkage; 14 asymptomatic occlusions occurred in the persisting shrinkage group.…”
Section: Discussionmentioning
confidence: 99%
“…Device-induced aneurysm sac significant changes might alter the device integrity. 20,21 Improved device designs more prone to inducing significant AAA exclusion might also be more likely to be crushed by the aneurysmal sac collapse together with loss of patency. In our study, iliac branch occlusions were more likely found in aneurysms with any shrinkage; 14 asymptomatic occlusions occurred in the persisting shrinkage group.…”
Section: Discussionmentioning
confidence: 99%
“…However, to date, the main issue of EVAR remains stent graft (SG) durability. Secondary interventions after 5 years are required in up to 22% of abdominal aortic aneurysms because of endoleaks, stenosis or thrombosis of the SG, and failure of the SG components [1][2][3][4][5][6]. Despite much more limited number of reports, complications following endovascular repair of iliac aneurysms are similar [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…Endoleak, graft migration, and aneurysm sac enlargement constitute the remaining shortcomings of endovascular aneurysm repair and underlie the observed loss of comparative clinical benefit during long-term follow-up. [3][4][5][6] The Nellix device (Endologix, Irvine, Calif) was developed with recognition that many of the complications of endovascular aortic aneurysm repair stem from inadequate isolation of the native aortic wall from pressurized blood flow. The highly differentiated Nellix platform uses polymer-filled polyurethane EndoBags surrounding balloon-expandable stents covered with expanded polytetrafluoroethylene and stabilizes the aneurysm sac by completely filling and sealing the blood flow lumen, hence the name EndoVascular Aneurysm Sealing (EVAS) system.…”