2002
DOI: 10.1103/physrevb.65.125406
|View full text |Cite
|
Sign up to set email alerts
|

Second-harmonic imaging of the absolute polar molecular orientation at interfaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2003
2003
2010
2010

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…In general, unfortunately, when laser beams are scanned angu- larly by a galvano mirror system through an objective lens, they essentially travel different path lengths within highly dispersive lens media for different angular positions. 9 This effect is more pronounced especially for very thick lenses such as high-NA objectives made of a stack of many lenses with sophisticate designs. This resembles the situation of changing PSU thickness, and consequently results in a reduced field of view within which the interferometric effort pays.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In general, unfortunately, when laser beams are scanned angu- larly by a galvano mirror system through an objective lens, they essentially travel different path lengths within highly dispersive lens media for different angular positions. 9 This effect is more pronounced especially for very thick lenses such as high-NA objectives made of a stack of many lenses with sophisticate designs. This resembles the situation of changing PSU thickness, and consequently results in a reduced field of view within which the interferometric effort pays.…”
Section: Resultsmentioning
confidence: 99%
“…However, a strong nonresonant background might sometimes be very useful in terms of enhancing the resonant signal through a homodyne interferometric amplification and consequently improving the image quality. [8][9][10] In this paper, we set up a nonlinear optical interferometer to see how CARS imaging can be improved by interferometric implementations. The experimental scheme is different from conventional schemes that have been tried elsewhere for imaging purpose.…”
Section: Introductionmentioning
confidence: 99%
“…Surface-SHG (S-SHG) uses TIR of a pulsed IR beam so that the SHG efficiency of the surface can be evaluated selectively. S-SHG is a well-established optical technique for studying non-linear materials with high surface/interface specificity [95][96][97][98]. Again, the use of a gold film on the interface can be used to provide a signal enhancement [99].…”
Section: Surface Second-harmonic Generationmentioning
confidence: 99%
“…Over the past twenty years, many spectroscopic techniques have been utilized to investigate the average molecular orientation at the interface, such as second-harmonic generation, [8][9][10][11] fluorescence, 12 attenuated total internal reflection, 12,13 linear dichroism, 12,14,15 and photoacoustic spectroscopy. 11 Recently, cavity ring-down spectroscopy (CRDS) has also been used to carry out molecular orientation studies.…”
Section: Introductionmentioning
confidence: 99%
“…Over the past twenty years, many spectroscopic techniques have been utilized to investigate the average molecular orientation at the interface, such as second-harmonic generation, fluorescence, attenuated total internal reflection, , linear dichroism, ,, and photoacoustic spectroscopy …”
Section: Introductionmentioning
confidence: 99%