2017
DOI: 10.1007/s10404-017-1941-4
|View full text |Cite
|
Sign up to set email alerts
|

SEBS elastomers for fabrication of microfluidic devices with reduced drug absorption by injection molding and extrusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
66
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 68 publications
(71 citation statements)
references
References 31 publications
4
66
0
1
Order By: Relevance
“…Although PDMS holds many favorable properties for manufacturing microfluidic organ devices, it also has the potential drawback of adsorbing small and hydrophobic molecules. 61 , 62 To overcome this, surface modification of PDMS or alternative polymeric (eg, polyurethane, styrenic block copolymers) 63 or ECM-based materials 64 could potentially be used in studies designed to predict drug bioavailability or absorption. Alternatively, when using Organ Chips to model drug PK and PD, PDMS adsorption can be taken into account using computational modeling for most compounds.…”
Section: Limitations Of Human Intestine Chip Modelsmentioning
confidence: 99%
“…Although PDMS holds many favorable properties for manufacturing microfluidic organ devices, it also has the potential drawback of adsorbing small and hydrophobic molecules. 61 , 62 To overcome this, surface modification of PDMS or alternative polymeric (eg, polyurethane, styrenic block copolymers) 63 or ECM-based materials 64 could potentially be used in studies designed to predict drug bioavailability or absorption. Alternatively, when using Organ Chips to model drug PK and PD, PDMS adsorption can be taken into account using computational modeling for most compounds.…”
Section: Limitations Of Human Intestine Chip Modelsmentioning
confidence: 99%
“…Further advancement needs to be made in terms of recapitulating both healthy and diseased tissues. This may be further promoted by materials' development, such as finding substitutes for PDMS . While PDMS is clear, flexible, heat resistant, and enables gas exchange, it can absorb hydrophobic substances and can interact with polar compounds .…”
Section: Microfluidic In Vitro Systems: the Isocmentioning
confidence: 99%
“…OSTEs thiol-ene ratios can also be tuned to allow fabrication of flexible devices and thus produce mechanically actuated components (Carlborg et al, 2011). Other materials, intended as a bridge between PDMS and thermoplastics in terms of high-throughput fabrication and material characteristics, are styrene-ethylene-butylene-styrene (SEBS) block copolymers (Domansky et al, 2017). For biomedical applications, the focus has shifted from PDMS-like materials towards bio-based materials such as silk and hydrogels, due to their biodegradability and surface and topographical properties (Konwarh et al, 2016), (Zhao et al, 2016).…”
Section: Accepted Manuscriptmentioning