2022
DOI: 10.1007/s11356-022-23239-7
|View full text |Cite
|
Sign up to set email alerts
|

Seasonal variations of natural organic matter (NOM) in surface water supplied to two coal-fired power stations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…This has been proven by Ruhl et al (2012), who investigated the elution behavior of a large set of low MW acid compounds with LC-OCD-OND and showed that their elution occurs over the entire humic substances peak and not only in the shoulder, which is denoted as the low MW acid peak [23,24]. LC-OCD-OND has been applied in various studies to investigate the performance of drinking water treatment processes and/or to assess the impact of altering NOM characteristics in the source water on these processes [25][26][27][28], e.g., MacKeown et al (2021) found a correlation between trihalomethane formation potential and the concentration of building blocks in the water [26]. A drawback of LC-OCD-OND is that its implementation and data interpretation are still relatively complex, which impedes its use in routine analysis.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This has been proven by Ruhl et al (2012), who investigated the elution behavior of a large set of low MW acid compounds with LC-OCD-OND and showed that their elution occurs over the entire humic substances peak and not only in the shoulder, which is denoted as the low MW acid peak [23,24]. LC-OCD-OND has been applied in various studies to investigate the performance of drinking water treatment processes and/or to assess the impact of altering NOM characteristics in the source water on these processes [25][26][27][28], e.g., MacKeown et al (2021) found a correlation between trihalomethane formation potential and the concentration of building blocks in the water [26]. A drawback of LC-OCD-OND is that its implementation and data interpretation are still relatively complex, which impedes its use in routine analysis.…”
Section: Introductionmentioning
confidence: 99%
“…The efficiency of the degassing unit to remove IC was therefore investigated using IC standards. The standards ranged between 2.5 and 80 mgC dm −3 and were prepared using Na 2 CO 3 (5,15,25,40,60, 80 mgC dm −3 ) or K 2 CO 3 (2.5, 7.5, 10, 20, 30, 50, 70 mgC dm −3 ) in MilliQ. The standards were measured with the Shimadzu TOC V CPN to determine the exact IC concentration of the prepared standards and with the HPSEC-TOC system to determine the amount of IC that was not removed by the degassing unit.…”
mentioning
confidence: 99%