2017
DOI: 10.48550/arxiv.1710.11608
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Search for Zero-Neutrino Double Beta Decay in 76Ge with the Majorana Demonstrator

C. E. Aalseth,
N. Abgrall,
E. Aguayo
et al.

Abstract: The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76 Ge. The Majorana Demonstrator comprises 44.1 kg of Ge detectors (29.7 kg enriched in 76 Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV … Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
43
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(43 citation statements)
references
References 20 publications
0
43
0
Order By: Relevance
“…The lowest background runs (E = 5.24 kg•yr) yield a BI of 1.6 +1.2 −1.0 •10 −3 cts/(keV•kg•yr), being compatible with the projected background level of 3 cts/(ROI•t•yr) based on the material assay. At E = 10 kg•yr no 0νββ signal candidate has been observed which implies a lower limit of T 0ν 1/2 > 1.9 • 10 25 yr (90% CL) [18].…”
Section: The Majorana Demonstratormentioning
confidence: 90%
See 1 more Smart Citation
“…The lowest background runs (E = 5.24 kg•yr) yield a BI of 1.6 +1.2 −1.0 •10 −3 cts/(keV•kg•yr), being compatible with the projected background level of 3 cts/(ROI•t•yr) based on the material assay. At E = 10 kg•yr no 0νββ signal candidate has been observed which implies a lower limit of T 0ν 1/2 > 1.9 • 10 25 yr (90% CL) [18].…”
Section: The Majorana Demonstratormentioning
confidence: 90%
“…With 2.5 (1) keV FWHM resolution at Q ββ , the MJD has achieved the best energy resolution of any 0νββ decay experiment [18], and its sub-keV threshold allowed to perform sensitive tests of physics beyond the SM [19]. The lowest background runs (E = 5.24 kg•yr) yield a BI of 1.6 +1.2 −1.0 •10 −3 cts/(keV•kg•yr), being compatible with the projected background level of 3 cts/(ROI•t•yr) based on the material assay.…”
Section: The Majorana Demonstratormentioning
confidence: 99%
“…With the completion of construction and the achievement of near-background free data in a 360 keV ROI around the 0νββ Q-value, the MAJORANA DEMONSTRATOR has released its first 0νββ limit 16 . The experiment will continue data taking, with 0νββ sensitivity projected to increase linearly under the current background conditions.…”
Section: Discussionmentioning
confidence: 99%
“…From this exposure, approximately 10 kg yr were selected for a 0νββ analysis with a lowest background index of 1.6 +1.2 −1.0 × 10 −3 c (keV kg yr) −1 , as detailed in Ref. 16. A profile likelihood method was used to determine a 0νββ half-life and background rate that best fit the data.…”
Section: Measuring the 0νββ Half-lifementioning
confidence: 99%
See 1 more Smart Citation