Screening of Heparin API by Near Infrared Reflectance and Raman Spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
32
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(32 citation statements)
references
References 22 publications
0
32
0
Order By: Relevance
“…Since the initial report discovery and structural elucidation of OSCS in heparin (13), a number of analytical tools and methods have been used in the overall analysis and are described in a series of recent publications, including NMR (23)(24)(25), MS (26), IR-Raman (27,28), CE (29 -31), HPLC (32), biosensor (33), and bioassays (34 -36). Also, the structural assignment of OSCS has been independently confirmed by other independent investigations (41), providing additional support to the fact that OSCS is the major contaminant within suspect heparin lots.…”
Section: Discussionmentioning
confidence: 99%
“…Since the initial report discovery and structural elucidation of OSCS in heparin (13), a number of analytical tools and methods have been used in the overall analysis and are described in a series of recent publications, including NMR (23)(24)(25), MS (26), IR-Raman (27,28), CE (29 -31), HPLC (32), biosensor (33), and bioassays (34 -36). Also, the structural assignment of OSCS has been independently confirmed by other independent investigations (41), providing additional support to the fact that OSCS is the major contaminant within suspect heparin lots.…”
Section: Discussionmentioning
confidence: 99%
“…12,13 However, development of additional, orthogonal assays that can rapidly and sensitively detect the presence of potential contaminants, if present, is warranted. To this end, there have been several reports of potential methods, including ion exchange HPLC, 10 quantitative capillary electrophoresis, 14 inhibition of Taq polymerase in a real-time PCR, 15 a fluorescent receptor array, 16 and use of potentiometric polyanion sensors.…”
mentioning
confidence: 99%
“…An advantage of both NIR and Raman spectroscopy is that they can be used to characterize solid heparin samples and detect OSCS contamination above 1% [48]. A nondestructive NIR method has been extended beyond impurity analysis as a potential tool for heparin potency determination [49].…”
Section: New Analytical Methods For Heparin Impurity Analysismentioning
confidence: 99%