2014
DOI: 10.1016/j.chemosphere.2014.01.064
|View full text |Cite
|
Sign up to set email alerts
|

Screening and analysis of 940 organic micro-pollutants in river sediments in Vietnam using an automated identification and quantification database system for GC–MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
27
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 77 publications
(28 citation statements)
references
References 46 publications
0
27
1
Order By: Relevance
“…GC coupled to tandem MS is a relatively new analytical technique which provides reliability and sensitivity for the trace analysis of environmental micropollutants including phthalates [32]. In the present improved method, nine phthalate esters (DMP, DEP, DBP, DHP, BBP, DBEP, DEHP, DNOP and DINP) were selected as model compounds, since they prove to be the most common phthalate contaminants in food and contact materials [25] and therefore, all of these phthalates should be included in the validated methods.…”
Section: Discussionmentioning
confidence: 99%
“…GC coupled to tandem MS is a relatively new analytical technique which provides reliability and sensitivity for the trace analysis of environmental micropollutants including phthalates [32]. In the present improved method, nine phthalate esters (DMP, DEP, DBP, DHP, BBP, DBEP, DEHP, DNOP and DINP) were selected as model compounds, since they prove to be the most common phthalate contaminants in food and contact materials [25] and therefore, all of these phthalates should be included in the validated methods.…”
Section: Discussionmentioning
confidence: 99%
“…Each compound identified via the NIST 14 Library Search report has a corresponding mass spectrum showing the abundance of the possible numerous m/z peaks per compound (Ademiluyi et al, ; Duong, Kadokami, Pan, Matsuura, & Nguyen, ).…”
Section: Methodsmentioning
confidence: 99%
“…Prior to analysis, the MS was auto-tuned to perfluorotributylamine (PFTBA) using already established criteria to check the abundance of m/z 69, 219, 502 and other mechanism optimal and sensitivity conditions. Each compound identified via the NIST 14 Library Search report has a corresponding mass spectrum showing the abundance of the possible numerous m/z peaks per compound (Ademiluyi et al, 2016;Duong, Kadokami, Pan, Matsuura, & Nguyen, 2014).…”
Section: Gc-ms Quantification Of Alkaloid Constituentsmentioning
confidence: 99%
“…Researchers have demonstrated the usefulness of using quantitative data for source identification [e.g. Pan et al (2014), Duong et al (2014), Bu et al (2009)]. However, qualitative data could usually be easily obtained than quantitative ones, especially in the high throughout screening analysis.…”
Section: Evaluation Of the Usefulness Of Qualitative Datamentioning
confidence: 99%