2021
DOI: 10.1002/pro.4224
|View full text |Cite
|
Sign up to set email alerts
|

DIALS as a toolkit

Abstract: The DIALS software for the processing of X-ray diffraction data is presented, with an emphasis on how the suite may be used as a toolkit for data processing. The description starts with an overview of the history and intent of the toolkit, usage as an automated system, command-line use, and ultimately how new tools can be written using the API to perform bespoke analysis. Consideration is also made to the application of DIALS to techniques outside of macromolecular X-ray crystallography.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
45
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
2
2

Relationship

2
8

Authors

Journals

citations
Cited by 78 publications
(45 citation statements)
references
References 37 publications
0
45
0
Order By: Relevance
“…Diffraction data were collected on beamline I0-3 at the Diamond Light Source at 100 K using a wavelength of 0.9762 Å. Data were processed using Dials 97 via Xia2 98 and Aimless 99 within CCP4i2. 100 The datasets were phased using Molrep 101 and the M pro apo structure (PDB ID: 6YB7).…”
Section: Methodsmentioning
confidence: 99%
“…Diffraction data were collected on beamline I0-3 at the Diamond Light Source at 100 K using a wavelength of 0.9762 Å. Data were processed using Dials 97 via Xia2 98 and Aimless 99 within CCP4i2. 100 The datasets were phased using Molrep 101 and the M pro apo structure (PDB ID: 6YB7).…”
Section: Methodsmentioning
confidence: 99%
“…After symmetry determination, an overall best estimate of the unit cell is obtained by refinement of the unit cell parameters against the observed 2 θ angles, using the program (Winter et al ., 2021). This program minimises the unit cell constants against the difference between observed and calculated 2 θ values, which are determined from background-subtracted integrated centroids.…”
Section: Methodsmentioning
confidence: 99%
“…After symmetry determination, an overall best estimate of the unit cell is obtained by refinement of the unit-cell parameters against the observed 2 angles using dials.two_ theta_refine (Winter et al, 2022). This program minimizes the unit-cell constants against the difference between observed and calculated 2 values, which are determined from background-subtracted integrated centroids.…”
Section: Unit-cell Refinementmentioning
confidence: 99%