Scanning optical pyrometer for measuring temperatures in hollow cathodes

Abstract: Life-limiting processes in hollow cathodes are determined largely by the temperature of the electron emitter. To support cathode life assessment, a noncontact temperature measurement technique which employs a stepper motor-driven fiber optic probe was developed. The probe is driven inside the hollow cathode and collects light radiated by the hot interior surface of the emitter. Ratio pyrometry is used to determine the axial temperature profile. Thermocouples on the orifice plate provide measurements of the ext… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…21 However, temperature decreases of this magnitude over a period of several hundred hours have been observed at the beginning of long duration tests. 24 The temperature decrease is generally attributed to long term conditioning of the emitter surface (removal of reactive contaminants and achieving a stable surface morphology and crystal structure) which results in a decrease in the work function.…”
Section: Comparison Of Experimental and Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…21 However, temperature decreases of this magnitude over a period of several hundred hours have been observed at the beginning of long duration tests. 24 The temperature decrease is generally attributed to long term conditioning of the emitter surface (removal of reactive contaminants and achieving a stable surface morphology and crystal structure) which results in a decrease in the work function.…”
Section: Comparison Of Experimental and Simulation Resultsmentioning
confidence: 99%
“…The temperature distribution measured along the axis of an emitter with the same geometry and operating conditions as the LDT cathode 21 was used in the simulations. The Ba partial pressure in the insert plasma near the emitter surface is calculated as part of the barium Ba solution.…”
mentioning
confidence: 99%
“…Tests at JPL (for both cathode assemblies) will also be performed to measure the emitter temperature and the plasma properties inside the emitter region and along the cathode centerline. 46,47 These detailed internal cathode measurements will be used, in conjunction with simulations using the 2-D axisymmetric Orificed Cathode (OrCa2D) code, to obtain accurate estimates of cathode life. 48 , 49 An inner electromagnet test coil was fabricated, and instrumented with over 15 thermocouples.…”
Section: Component Testingmentioning
confidence: 99%
“…[14,15], were conducted in a vacuum facility at a base pressure of 10 −6 Torr. The cathode is of the standard configuration shown in the drawing in Propellant-grade xenon (99.9995% purity) was injected through the hollow cathode.…”
Section: Methodsmentioning
confidence: 99%