2017
DOI: 10.1016/j.ijadhadh.2016.11.006
|View full text |Cite
|
Sign up to set email alerts
|

Scanning Kelvin Probe Blister test measurements of adhesive delamination – Bridging the gap between experiment and theory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 31 publications
0
5
0
Order By: Relevance
“…In their conclusions they state that the shear strength of the joints is proportional to the effective interfacial surface area, thereby rejecting the concept of additional mechanical interlocking. Besides mechanical testing to study the initial and residual adhesion, the scanning Kelvin probe (SKP) has shown to be a high-resolution technique for in-situ assessment of the interfacial stability for both coatings and adhesives, by measuring the corrosion potential of the buried electrode at the metal/polymer interface [8][9][10][11]. Khun and Frankel used the SKP to study the effect of surface roughness and texture on the kinetics of cathodic delamination of epoxy coated steel [12].…”
Section: Introductionmentioning
confidence: 99%
“…In their conclusions they state that the shear strength of the joints is proportional to the effective interfacial surface area, thereby rejecting the concept of additional mechanical interlocking. Besides mechanical testing to study the initial and residual adhesion, the scanning Kelvin probe (SKP) has shown to be a high-resolution technique for in-situ assessment of the interfacial stability for both coatings and adhesives, by measuring the corrosion potential of the buried electrode at the metal/polymer interface [8][9][10][11]. Khun and Frankel used the SKP to study the effect of surface roughness and texture on the kinetics of cathodic delamination of epoxy coated steel [12].…”
Section: Introductionmentioning
confidence: 99%
“…In terms of Scanning Kelvin Probe (SKP), it is commonly employed to determine the coating failure of poorly conductive materials instead of conductive materials by measuring the work function or Volta Contact Potential Difference (VCPD) of the material [94,95]. SKP utilizes a Kelvin probe near the surface of the specimen to form a capacitor, as shown in Figure 5 [96].…”
Section: E Scanning Kelvin Probementioning
confidence: 99%
“…80,115,116 High resolution (HR) SKP BT was combined with finite element simulations to establish the connection between first principles and experimental observations. 117 Figure 19 provides the information on the applications of SKP/SKPFM in diverse areas related to corrosion.…”
Section: Examples Of Use In Corrosion Researchmentioning
confidence: 99%